background image

1.  

2.  

HPE Knowledge Article

HPE OfficeConnect 1910 Switch Series - How to Connect Serial Cable to the

Switch and Setup Configuration

Article Number mmr_sf-EN_US000005201

Environment

HPE 1910 Switch

Issue

How to connect serial cable to switch

How to setup configuration

How to check default IP address

How to add IP address

Cause

Resolution

1.Setting up the configuration environment: To set up the configuration environment, connect a terminal (a PC in this example) to the console port on the

switch with a console cable. A console cable is an 8-core shielded cable, with a crimped RJ-45 connector at one end for connecting to the console port of

the switch, and a DB-9 female connector at the other end for connecting to the serial port on the console terminal.

Use a console cable to connect a terminal device to the switch, as follows:

Plug the DB-9 female connector to the serial port of the console terminal or PC.

Connect the RJ-45 connector to the console port of the switch.

Содержание OfficeConnect 1910 Series

Страница 1: ...nment To set up the configuration environment connect a terminal a PC in this example to the console po switch with a console cable A console cable is an 8 core shielded cable with a crimped RJ 45 connector at one end for connecting to the conso the switch and a DB 9 female connector at the other end for connecting to the serial port on the console terminal Use a console cable to connect a termina...

Страница 2: ...nnector from the switch 2 Setting terminal parameters To configure and manage the switch you must run a terminal emulator program on the console terminal for example a PC This section uses Windows XP HyperTerminal as an example The following are the required terminal settings Bits per second 38400 Data bits 8 Parity None Stop bits 1 Flow control None Emulation VT100 Follow these steps to set termi...

Страница 3: ...Select the serial port to be used from the drop down list and click Connect using OK SetBits per second to 38400 Data bits to 8 Parity to None Stop bits to 1 and Flow control to None and click OK ...

Страница 4: ...Select File Properties in the HyperTerminal window ...

Страница 5: ...Click the Settings tab set the emulation to VT100 and click OK in the Switch Properties dialog box ...

Страница 6: ...ssword is required User admin passwords are case sensitive To log in to the CLI Press prompt displays Enter The Username Login authentication Username Enter your username at the prompt Username Username admin Press Enter prompt display The Password Password The login information is verified and displays the following CLI menu Switch ...

Страница 7: ...software image file from the TFTP server and specify as the startup configuration file upgrade server address source filename bootrom runtime Reboot the device and run the main configuration file reboot View the summary information of the device summary Ping a specified destination ping host Copyright 2016 Hewlett Packard Enterprise Development LP The information contained herein is subject to cha...

Отзывы: