background image

NOTE:

The illustration is for reference only. In a single-
controller system, remove the controller module
from module A, top location.

Installing the new controller module

Procedure

1.

With the latches in the open position, slide the
module into the enclosure as far as it will go (1). To
facilitate insertion, press firmly on the top-center of
the module, ensuring that the module is seated and
flush with the chassis.

2.

Rotate the latches upward to engage the module with
the internal connector (2) and turn the thumbscrews
finger-tight (3).

NOTE:

The illustration is for reference only. In a single-
controller system, insert the controller module
into module A, top location.

3.

Reconnect the cables.

After installing a controller in an operational, dual-
controller system, the new controller automatically
begins initializing. If the firmware versions differ
between the two controllers, the Partner Firmware
Update feature, if enabled, will update controller
firmware so that both controllers are running the
same firmware version.

4.

In operational systems, if additional hardware
components, such as a second controller, need
replacing or installing, wait 30 minutes before
proceeding with those procedures. This time frame
ensures that one or more controllers and their
ownership of vdisks or disk-groups are fully
stabilized.

Verifying proper operation

Examine the module status as indicated in 

LED

descriptions

.

If the replacement controller does not boot up as
expected or if the 

Fault/Service Required

 LED is

amber, the module is not online. Check the event log for
errors, and then restart the controller to put the module
online. To restart a controller, do the following:

Procedure

1.

Select the system in the Configuration View panel:

• For the P2000 SMU and the MSA 1040/2040

SMU v2 — select 

Tools > Shut Down or Restart

Controller

.

• For the MSA 1050/2050 SMU and the MSA

1040/2040 SMU v3 — select 

Restart System

from the System topic.

2.

Set the following options and then click 

OK

:

• Operation—

Restart

• Controller Type—

Storage

• Controller—

A

 or 

B

Verifying configuration settings

After replacing a controller, verify that your system
configuration settings are set properly. Repeat the
commands shown in 

Recording configuration settings

and compare the current values with those recorded
before the installation. If necessary, change the settings
to their previous values. For more information, see the

HPE MSA SMU Reference Guide

.

Page 4

Содержание MSA

Страница 1: ...in the enclosure Openings must be populated for the enclosure to cool properly Leave modules in the enclosure until a replacement is available Parts can be damaged by electrostatic discharge use proper anti static protection Keep parts in electrostatic containers until needed and ensure you are properly grounded when touching static sensitive components IMPORTANT When replacing both controllers in...

Страница 2: ...ings NTP settings System information name contact location and description User information Email notification settings SNMP notification settings syslog notification settings Scheduled tasks Hosts IDs and names Specific host IDs names and mappings For more information regarding these settings see the applicable MSA SMU documentation at http www hpe com info storage docs Partner Firmware Update du...

Страница 3: ...e Cache Status LED is off or it is flashing one tenth of a second ON and nine tenths of a second OFF In a single controller environment I O must be stopped and the enclosure must be powered off prior to the replacement In a dual controller environment if the failed controller is first shut down the controller may be hot replaced in an operational enclosure Procedure 1 If you are replacing a contro...

Страница 4: ... need replacing or installing wait 30 minutes before proceeding with those procedures This time frame ensures that one or more controllers and their ownership of vdisks or disk groups are fully stabilized Verifying proper operation Examine the module status as indicated in LED descriptions If the replacement controller does not boot up as expected or if the Fault Service Required LED is amber the ...

Страница 5: ... http www hpe com support msa1040 MSA 1040 product page http www hpe com support msa1040 P2000 G3 MSA manuals page http www hpe com support p2000G3msa P2000 G3 MSA product page http www hpe com support p2000G3msa HPE Passport for MSA arrays http h20564 www2 hpe com hpsc doc public display docLocale en_US docId emr_na c05349541 Documentation feedback Hewlett Packard Enterprise is committed to provi...

Отзывы: