138
Field Description
hyphen (-).
Detection Status
Power detection status of a PI:
•
Disabled
—PoE function is disabled.
•
Searching
—The PI is searching for the PD.
•
Delivering Power
—The PI is supplying power to the PD.
•
Fault
—A fault occurred during the test.
•
Test
—The PI is undergoing a test.
•
Other Fault
—A fault has caused the PSE to enter the idle status.
•
PD Disconnected
—The PD is disconnected.
On State Ports
Number of PIs that are supplying power.
Used
Power consumed by PIs on the PSE.
Remaining
Remaining power on the PSE.
display poe pse interface power
Use
display poe pse interface power
to display power information for PIs on a PSE.
Syntax
display poe pse
pse-id
interface power
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Parameters
pse
pse-id
: Specifies a PSE by its ID.
Usage guidelines
To display PSE ID and slot mappings, use the
display poe device
command.
This command is only available for the default MDC. For more information about MDCs, see
Virtual
Technologies Configuration Guide
.
Examples
# Display power information for PIs on PSE 7.
<Sysname> display poe pse 7 interface power
Interface Current Peak Max PD Description
(W) (W) (W)
GE1/0/25 4.4 4.5 4.6 IP Phone on Room 309 for Peter Smith
GE1/0/26 4.4 4.5 15.4 IP Phone on Room 409 for Peter Pan
GE1/0/27 15.0 15.3 15.4 Access Point on Room 509 for Peter
GE1/0/28 0.0 0.0 5.0 IP Phone on Room 609 for Peter John
GE1/0/29 0.0 0.0 4.0 IP Phone on Room 709 for Jack