15
2.
Power off the power supply and remove the power cord.
3.
Loosen the captive screws on the power supply with a Phillips screwdriver until they are
completely disengaged from the chassis.
4.
Grasp the handle of the power supply with one hand and pull the module part way out. Support
the module bottom with the other hand, and pull the power supply slowly along the guide rails
out of the slot.
5.
Place the removed power supply in an antistatic bag.
Figure 19 Removing a PSR150-A1 (JD362B) power supply
Connecting the power cord
CAUTION:
•
Provide a circuit breaker for each power cord.
•
Before connecting the power cord, make sure the circuit breaker on the power cord is turned off.
Table 5 Power cord connection procedures at a glance
Switch model
Available power source
Connection
procedure reference
•
HPE 5130 24G 4SFP+ EI
•
HPE 5130 24G 2SFP+ 2XGT EI
•
HPE 5130 24G 4SFP+ EI BR
AC power source
Connecting the switch to
an AC power source
•
HPE 5130 48G 4SFP+ EI
•
HPE 5130 24G SFP 4SFP+ EI
•
HPE 5130 48G 2SFP+ 2XGT EI
•
HPE 5130 48G 4SFP+ EI BR
AC power source
Connecting the switch to
an AC power source
–48 V DC power source in the
equipment room
Connecting the switch to
a –48 VDC power source
RPS
Recommended HPE RPS
models: A-RPS800 (JD183A )
and A-RPS1600 (JG136A)
Connecting the switch to
an RPS
•
HPE 5130 24G PoE+ 4SFP+ (370W) EI
•
HPE 5130 48G PoE+ 4SFP+ (370W) EI
AC power source