• LFF hot-plug drive
5. Determine the status of the drive from the drive LED definitions.
6. If removed, install the front bezel.
The installation is complete.
To configure arrays, see the HPE Smart Array SR Gen10 Configuration Guide at the
If you have installed SFF drives in the Apollo DX2800 Gen10 Chassis,
you can configure the drive bay mapping.
Installing an NVMe drive
NVMe drives are supported in the HPE Apollo DX2600 Gen10 Chassis and in the HPE Apollo DX2800 Gen10 Chassis. For
more information, see
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
CAUTION: The maximum inlet ambient temperature for most components installed in the system is 35°C (95°F).
Some components, however, are subject to thermal limitations depending on the chassis model and the fan
configuration. There are some hardware configurations where it is necessary to limit the number of drives installed
in the chassis. For more information, see Temperature requirements in the server user guide on the Hewlett
Packard Enterprise (
https://www.hpe.com/info/ApolloDX2000Gen10-docs).
Procedure
1. If installed, remove the front bezel.
2. Remove the drive blank.
Hardware options installation