background image

4/2/2009 

                828 

2

The steps listed as 

WARRANTY REQUIREMENT

 must be strictly followed to qualify for product     

warranty

. Warranty will be void if not followed. 

1)

 

SELECTING THE LOCATION: 

 

WARNING: 

COMPLETE FIRE PITS ARE DESIGNED FOR

 OUTDOOR USE. 

HEARTH PRODUCTS 

CONTROLS CO

. MUST BE NOTIFIED OF ANY OTHER USE. THIS PRODUCT MUST BE USED ONLY 

IN A FULLY VENTED (DAMPER FULLY OPEN IF INDOORS) AREA AND GLASS DOORS FULLY 
OPEN (IF INDOORS).   

 

 

 

WARNING: 

FIRE PITS CREATE VERY HIGH TEMPERATURES- IT IS VERY IMPORTANT 

 

THAT COMBUSTIBLES BE KEPT AT SAFE DISTANCES.

 

 

 

WARRANTY REQUIREMENT

: For installation of 110vac powered control systems, it is 

required to install a wall switch or breaker for the fire pit electrical outlet away from the enclosure 
to prevent unauthorized ignition of the fire pit.

 

 

WARRANTY REQUIREMENT

: The fire pit location must accommodate a gas shut off outside 

of fire pit enclosure. The gas line should be a minimum of 3/4” or larger based on fire pit size.

 

 

 

To enjoy your fire pit, select a well drained location that allows for sufficient clearance from 
combustible materials.  

 

 

Choose a location that allows easy access for installation and maintenance of the fire pit. Make 
sure that trees and shrubbery are well clear around and above the fire pit.  

 

 

Pick a location that allows sufficient horizontal room to enjoy the fire pit while allowing a safe 
distance from the heat and flame.

 

 

Select a location where the fire pit can be attended during operation.  Never leave an operating fire 
pit unattended or by someone not familiar with its operation or emergency shut off locations.

 

     

Wooden or solid surfaces such as granite or marble must be located far enough away that 

they do not reach a temperature of more than 100 degrees F plus ambient air temperature.

  

Example

: If surrounding air temperature is 70, the wood surface temperature must stay at or 

below 170 degrees F. 

 

Complete Fire Pit with Valve box 

 

 

 

 

    Under Valve Box 

              6” 

 

 

 

 

    Sides Surrounding Fire Pit          14” 
    Above Fire Pit                             96” 

2)

 

CONSTRUCTION OF THE ENCLOSURE: 

WARNING:

  THERE MUST BE AN ELECTRICAL (WALL SWITCH OR BREAKER) AND GAS 

SHUTOFF ON THE EXTERIOR OF THE FIRE PIT TO ALLOW FOR EASY ACCESS FOR SHUTDOWN 
OR IN THE CASE OF AN EMERGENCY. 

WARNING: 

ALWAYS USE PROPER MATERIALS AND CONSTRUCTION FOR GAS SUPPLY, 

POWER, AND ENCLOSURE. 

 

 

WARRANTY REQUIREMENT

: The enclosure must be constructed on a stable surface.  Make 

 

sure that the fire pit is high enough that the control box is above the grade to prevent water 

 

damage to the controls inside the box.  

NEVER

 install a fire pit below ground level. Drainage 

 

must be provided for the enclosure to prevent water accumulation leading to damage to 

 

components in the valve box.

 

 

WARRANTY REQUIREMENT

: The enclosure must incorporate (2) vents on at least one 

 

side at a minimum size of 

18 sq. inches each

 (Example: 3”x 6” or larger) to allow heat within the 

 

enclosure to escape from void around valve box. Failure to do so will result in the fire pit 

 

automatically shutting down when internal valve box temperature reaches 175º F. This could

 

lead 

 

to heat damage to internal components. 

Some enclosures may require more ventilation based 

 

on material, size, and extended use.

 

This vent may work as a drain as well to prevent water 

 

build up in enclosure.

 

 

WARRANTY REQUIREMENT

: The interior void space of the enclosure surrounding the 

 

valve box cannot be filled with any material (gravel, crushed rock, concrete, etc.)- It is a 

 

requirement to have a 

minimum of 6”

 under the valve box for proper ventilation.

 

 

Select materials that are non-combustible in both initial installation as well as over time.

 

 

Make sure that the structure is level.  We recommend the use of the installation collar (optional) 

 

that may be mortared into the surround.   

3)

 

INSTALLATION OF THE COMPLETE FIREPIT ASSEMBLY: 

WARNING: CONFIRM THIS APPLIANCE IS BUILT FOR GAS USED- NATURAL GAS OR LP. 
DO NOT USE NATURAL GAS APPLIANCE WITH LP OR LP APPLIANCE WITH NATURAL 
GAS. REFER TO LABEL ON THIS APPLIANCE.

 