356
MIB Reference Manual
Hub
Fibre channel wiring concentrator that collapses loop topology into physical
star topology. Nodes are automatically added when active and removed when
inactive.
Idle
Continuous transmission of an ordered set when no data is being transmitted
to maintain an active fibre channel link and synchronization. See also Fill
word.
IN_ID
Initial Identifier. The field in the CT_HDR that displays the port ID of the
client originator of a fibre channel services request.
Initiator
Server or workstation that initiates communications with storage devices
over a fibre channel network. See also Target.
IOD
In Order Delivery. A parameter that, when set, guarantees that frames are
delivered in order if possible, otherwise, frames are dropped.
IPA
Initial process associator. An identifier associated with a process at an
N_Port.
ISL
Interswitch Link. Fibre channel link from the E_Port of one switch to E_Port
of another.
Isolated E_Port
A port that is online but not operational between switches due to overlapping
domain ID or nonidentical parameters such as E_D_TOVs.
IU
Information Unit. An individual set of information as defined by higher-level
process protocol definition, or upper-level protocol mapping.
JBOD
Just a Bunch Of Disks. A number of disks connected in a single chassis to
one or more controllers. See also RAID.
K28.5
Special 10-bit character used to indicate beginning of transmission words
that perform fibre channel control and signaling functions. First seven bits
are comma pattern. See also Comma.
L_Port
Loop Port. Node or fabric port that can use loop protocol or fabric protocol.
See also Nonparticipating mode, Participating mode.
Latency
Time required to transmit a frame, from the time sent until time of arrival.
Link
As applies to fibre channel, a physical connection between two ports,
consisting of both transmit and receive fibres. See also Circuit.
Содержание Surestore 6164 - Switch
Страница 1: ...reference manual version 2 3 MIB www hp com ...
Страница 7: ...7 Revision History July 2001 First release ...
Страница 8: ...8 MIB Reference Manual ...
Страница 12: ...12 MIB Reference Manual ...
Страница 15: ...MIB II Object Types 15 Figure 2 Tree Structure for MIB II system interfaces at and ip Groups ...
Страница 16: ...16 MIB Reference Manual Figure 3 Tree Structure for MIB II icmp tcp udp and egp Groups ...
Страница 17: ...MIB II Object Types 17 Figure 4 Tree Structure for MIB II SNMP Group ...
Страница 98: ...98 MIB Reference Manual ...
Страница 100: ...100 MIB Reference Manual Figure 5 FAMGMT Overall Tree Structure See Figure 6 See Figure 7 See Figure 7 ...
Страница 101: ...Fibre Alliance MIB Object Types 101 Figure 6 Tree Structure for connSet Tables ...
Страница 102: ...102 MIB Reference Manual Figure 7 Tree Structure for trapReg Table and statSet Tables ...
Страница 184: ...184 MIB Reference Manual ...
Страница 186: ...186 MIB Reference Manual Figure 8 FE MIB Overall Tree Structure ...
Страница 187: ...FC Fabric Element MIB Object Types 187 Figure 9 Tree Structure for fcFeConfig and fcFeOpTables ...
Страница 188: ...188 MIB Reference Manual Figure 10 Tree Structure for fcFeError fcFeAcct and fcFeCap Tables ...
Страница 252: ...252 MIB Reference Manual ...
Страница 256: ...256 MIB Reference Manual Figure 12 Tree Structure for swSystem swFabric swAgtCfg swFCPort and swNs Groups ...
Страница 257: ...FC Switch MIB Object Types 257 Figure 13 Tree Structure for swEvent swFwSystem and swEndDevice Groups ...
Страница 348: ...348 MIB Reference Manual ...