HP Lefthand CLI | Commands |
25
configureRaid
This command reconfigures the RAID setting on a storage system.
Availability
: Windows, SAN/iQ
Version
: 8.0
Request Syntax
cliq configureRaid configuration= login= userName= passWord=
login
Required
The IP addresses or DNS-resolvable names of one or more storage
systems
userName
Conditional The authentication user name for the storage system. (Parameters
userName/passWord or groupName must be specified).
passWord
Conditional The password for the storage system. (Parameters userName/passWord
or groupName must be specified).
groupName
Conditional The name of the management group with cached credentials.
(Parameters userName/passWord or groupName must be specified).
configuration
Required
The RAID type to set. The possible RAID levels are reported with the cliq
getNsmInfo command.
Example
cliq configureRaid configuration="RAID 10" login=10.0.1.2
userName=admin passWord=secret
cliq configureRaid configuration="RAID 10"
connectVolume
This command connects an already present array volume to an application server host.
Availability
: Windows
Version
: 8.0
Request Syntax
cliq connectVolume volumeName= login= userName= passWord=
login
Required
The IP addresses or DNS-resolvable names of one or more storage
systems
userName
Conditional The authentication user name for the storage system. (Parameters
userName/passWord or groupName must be specified).
passWord
Conditional The password for the storage system. (Parameters userName/passWord
or groupName must be specified).
groupName
Conditional The name of the management group with cached credentials.
(Parameters userName/passWord or groupName must be specified).
volumeName
Required
The name of the volume
initiatorport
Optional
The initiator port number.
persistent
Optional
Automatically restore iSCSI connection when the computer starts up.