Performing the system test
The system test exercises overall library functionality by moving cartridges within the library.
• During each cycle, the library moves a cartridge from a full slot to an empty slot and then return it to its
original slot. You can select the number of cycles for the test. If the test is cancelled, the library will
return the cartridge to its original slot.
• The library will not move cleaning cartridges during the test.
• The test operates over the whole library and does not consider partition configuration.
• During the test, the library is off line.
Prerequisites
• The library must contain at least one compatible cartridge for each generation of tape drive in the
library.
• The tape drives must be empty before starting the test.
To remove a tape from a tape drive, first try using the backup application or Move Media command
from the OCP or RMI. If neither of these methods work, see
Forcing a drive to eject a cartridge
page 110.
Procedure
1.
Navigate to the
Maintenance > Library Tests > System Test
screen.
2.
Select the number of test cycles.
3.
Select the media handling option:
•
Seating
—The cartridge is loaded into the tape drive but is not threaded onto the take up reel.
Choose this option for a faster test.
•
Threading
—The cartridge is loaded into the tape drive and threaded in the drive. Choose this
option for a complete test of the tape drive mechanical operation.
4.
Click
Start Test
.
Performing the slot to slot test
The slot to slot test randomly exchanges cartridges between slots to verify that the library is operating
correctly. At the end of the test, the cartridges are NOT returned to their original slots. If a data cartridge is
moved to an incompatible drive, the drive will reject the cartridge, as designed.
CAUTION:
The test can move cartridges between partitions.
For service and diagnostics, use the robotic test. See
on page 100.
98
Performing the system test