The HP SureStore E Disk Array XP512 Hardware
35
UNIT EMERGENCY POWER OFF
A switch is provided on the control panel on the front side of the disk
control frame (DKC) for an emergency powering off.
If you encounter any abnormality such as an abnormal sound, smell, or
smoke, power off the disk subsystem by operating the UNIT
EMERGENCY POWER OFF switch following the procedure below. The
procedure for operating the switch is as follows:
1. Push the control panel cover at the portion where PUSH is marked, open
the control panel cover, then operate the UNIT EMERGENCY POWER
OFF switch.
2. In using a UNIT EMERGENCY POWER OFF switch, first pull it up
and then pull it toward you as illustrated in figure 6 (page 36).
Caution
Pulling a UNIT EMERGENCY POWER OFF switch on the disk controller
instantly shuts down the storage subsystem, neglecting the system’s
power-off sequence. Jobs in process are aborted, and their integrity after
recovery is not guaranteed. Therefore, this method should be used only in
an emergency and not in usual maintenance.
Caution
The UNIT EMERGENCY POWER OFF switch on the disk controller
provides only partial power-off capability. AC input power remains present
at the primary circuit. Therefore, do not use the switches on these units
unless you need to power off the unit as an emergency measure.
When pulled, a UNIT EMERGENCY POWER OFF switch locks itself to
prevent further powering on and requires a trained and qualified HP field
engineer for recovery.
Содержание StorageWorks XP48 - Disk Array
Страница 1: ...HP SureStore E Disk Array XP512 HP SureStore E Disk Array XP48 H Owner s Guide ...
Страница 19: ...19 2 THE HP SURESTORE E DISK ARRAY XP512 HARDWARE ...
Страница 45: ...45 3 THE HP SURESTORE E DISK ARRAY XP48 HARDWARE ...
Страница 56: ...56 HP SureStore E Disk Array XP512 XP48 Owner s Guide Figure 10 Pulling the UNIT EMERGENCY POWER OFF Switch ...
Страница 69: ...The HP SureStore E Disk Array XP Family of Optional Software 69 Figure 11 Remote Control XP Menus ...
Страница 76: ...76 HP SureStore E Disk Array XP512 XP48 Owner s Guide ...
Страница 86: ...86 HP SureStore E Disk Array XP512 XP48 Owner s Guide VCCI EMC Statement Japan ...
Страница 87: ...Regulatory Statements 87 BSMI EMC License Number and Statement Taiwan XP512 XP48 ...
Страница 88: ...88 HP SureStore E Disk Array XP512 XP48 Owner s Guide Harmonics Conformance Japan ...
Страница 94: ...94 HP SureStore E Disk Array XP512 XP48 Owner s Guide ...
Страница 106: ...106 HP SureStore E Disk Array XP512 XP48 Owner s Guide ...
Страница 116: ...116 HP SureStore E Disk Array XP512 XP48 Owner s Guide ...