11 

11 

11 

11 

11  Configure the MSA1510i

The following methods are available to initially configure the MSA1510i:

Storage Management Utility, Initial System Configuration Wizard

Storage Management Utility, user interface

MSA1510i Command Line Interface

Storage Management Utility, Initial System Configuration Wizard

The wizard is the easiest and simplest method of configuring your system. You

are prompted in a logical sequence for storage, iSCSI, logon, and management

settings. Then, the wizard uses those settings to configure the storage and make it

available on the network. Depending on the characteristics and number of

physical hard drives in the storage enclosures, and the selected RAID level, one

or more large logical drives are created and mapped to one target. After

completing the wizard, the main user interface of the Storage Management

Utility (SMU) is displayed, for you to enter security settings and manage the

storage. The wizard is the best configuration method for single-server

environments needing bulk storage.

Storage Management Utility, main user interface

The Storage Management Utility main user interface (SMU) can be used to

initially configure the system, as well as manage the storage. The SMU offers

more flexibility when configuring the physical hard drives into logical droves

units. The SMU is the best configuration method for multi-server environments that

need to customize the storage configuration and control access to the storage.

Command Line Interface

The MSA1510i Command Line Interface (CLI) offers a command level method of

configuring and managing the storage, and is provided for system administrators

who prefer this method of system management.

NOTE:

NOTE:

NOTE:

NOTE:

NOTE:

 

The following instructions detail using the SMU Initial  System Configuration Wizard. For

information about the SMU, see the 

HP Storage Management Utility user guide

. For information

about the Command Line Interface, see the 

HP StorageWorks MSA1510i Command Line

Interface reference guide

.

1. Access the HP Storage Management Utility:

- From a workstation on the MSA1510i LAN segment, open a Web browser.
- Enter the IP address of the MSA1510i controller management port,

  displayed on the controller LCD panel.

NO

NO

NO

NO

NOTE:

TE:

TE:

TE:

TE:

 

You may need to modify the IP Address of the management device to be in the same

subnet as the default address assigned to the MSA1510i management port.

2. When prompted, enter the following default access permissions:

Username: root

Password:

root

NOTE:

NOTE:

NOTE:

NOTE:

NOTE:

 When prompted, change these defaults to user-defined values.

3. When the utility opens:

- Click 

OK 

to use the wizard.

- Click 

Cancel 

to use the SMU.

4. In the Welcome window, click 

Next

.

5. In the Storage Configuration window, enter the settings to use.

The wizard provides suggestions, unique to each MSA1510i installation,

based on the detected number of storage enclosures, enclosure type (SATA or

SCSI), number of drives, drive type, speed, size, and other criteria.

6. In the iSCSI Configuration window, enter the values for your iSCSI network,

along with initiator and target information.

7. In the Logon Settings window, specify if you want to change the username

and password for future access to the Storage Management Utility.

8. In the Management Settings window, enter settings for the SMU.

NOTE:

 The wizard defaults to the IP address assigned during the startup routine. Change

this to the static address you want to use for management traffic.

9. After completing all steps of the wizard, a confirmation window is

displayed:
- Click 

Finish 

to apply the settings.

- Click 

Cancel 

to change the settings.

While the utility applies the settings, a progress bar is displayed.

When configuration is complete, a completion message is displayed.

10. Modify the IP Address of the management device to be in the same

subnet as the static address assigned to the MSA1510i management port.

11. Access the SMU and navigate through the tabs of the interface, to

familiarize yourself with the interface, your initial configuration, and the

available options.
For information about using the SMU, see the 

HP Storage Management

Utility user guide

, available on the MSA1510i documentation CD and the

MSA1510i web site.

12. Configure the iSCSI initiator:

- Define the target portal.
- Logon to the available targets.

NO

NO

NO

NO

NOTE:

TE:

TE:

TE:

TE:

 

When configuring the iSCSI initiator, be sure to check 

Automatically restore

this connection when the system boots

.

SATA

15264

SATA

15242

SCSI cable connections to storage enclosures

(supported and unsupported)

SATA

SATA

15243

SCSI

15244

SATA

SCSI

15245

SCSI

SCSI

15246

Sample MSA1510i configuration

8  Connect the cables

Connect redundant power supplies of a device to separate power

sources. If you have only one UPS, maintain separate power paths by

plugging one power supply to the UPS on one power source and the

other power supply to a separate power source.

Use qualified Category 5e (or better) Ethernet cables.

Ensure that the cabling does not interfere with system operation or

maintenance. Bind the cables loosely with cable ties and route the excess

cables out of the way, along the side of the rack.

Attach a label near both ends of each cable to identify the device

connected to that cable.

Color-code both ends of each cable, to help visually identify a particular

cable without having to read or locate the label.

On the server:

Connect the NICs to the network switch.

On the MSA1510i:

Connect to the network switch (

1

).

Connect to the storage enclosures (

2

).

Connect to two separate power sources (

3

).

In redundant configurations, connect to the redundant switch (

4

).

15220

1

4

2

3

9  Power on the components

1. Verify that the following devices are powered on and in a ready state:

  Uninterruptable Power Supplies (UPS)

  Storage enclosures

 

 Ethernet network switches

2. Start up the MSA1510i by pressing the Power/Standby button on the front of

the device.

3. Wait for the MSA1510i startup routine to complete.

NO

NO

NO

NO

NOTE:

TE:

TE:

TE:

TE: 

If a redundant MSA1510i controller and 2-Port Ethernet iSCSI module are installed

in the MSA1510i, the 

CLONE FIRMWARE

 message might be displayed on the controller.

Press 

to copy the firmware from one controller to the other, so that the same firmware

version is installed on the controllers.

4. Press the 

and 

LCD panel message buttons on the front of each

MSA1510i controller, and look for the following messages:

MSA1510i Startup Complete

IP Address <

ip address>

Array controller firmware ver <

version>

5. Record the MSA1510i controller management port IP Address and the

firmware version on the other side of this document.

NOTE:

NOTE:

NOTE:

NOTE:

NOTE: 

If the server is powered on before the MSA1510i startup routine is completed, the

server may not properly discover the storage.

6. Power on (or restart) each server with access to the MSA1510i, and log on as

a user with administrative control.

7. Verify that each device in the network is operating properly:

  Read switch and server event logs.

  Read messages on the MSA1510i display panel.

  View status lights (LEDs) on each device.

  

Verify that the MSA1510i controller Heartbeat LED (

1

) is blinking.

  

Verify that the MSA1510i controller Link State LED (

2

) is on.

15192

1

2

Web sites

MSA1510i: 

http://h18006.www.1.hp.com/products/storageworks/msa1510i

This site includes important information about your MSA, and is updated to

include the latest specification and compatibility information, controller firmware,

iSCSI initiator, MPIO multipathing software, release notes, and user

documentation.

Storage enclosures: 

http://www.hp.com/storage

Servers: 

http://www.hp.com/go/servers

Ethernet network switches: 

http://www.hp.com/rnd

Ethernet network interface cards (NICs):

http://www.hp.com/servers/networking

Systems Insight Manager (SIM):

http://www.hp.com/go/hpsim

Web Based Enterprise Services (WEBES):

http://h18023.www1.hp.com/support/svctools/webes/index.html

Open Service Event Manager (OSEM):

http://h18023.www1.hp.com/support/svctools/osem/index.html

Multipathing (on the MSA1510i web site):

http://h18006.www.1.hp.com/products/storageworks/msa1510i

Clustering (High Availability): 

http://www.hp.com/go/ha

10 

10 

10 

10 

10  Record system information

If you have not yet done so, record information about the servers, switches, and

the MSA1510i on the worksheet on the other side of this document.
This information is required when configuring the MSA1510i, its storage, and the

iSCSI network, and is helpful for future configuration changes and

troubleshooting.

1

 

Server

5

 

Redundant Ethernet network switch

2

 

Ethernet network switch

6

 

Redundant 2-Port Ethernet module

3

 

MSA1510i

Redundant Ethernet cabling path

4

 

MSA20 SATA storage enclosure

15219

1

2

3

6

5

7

4

NOTE:

 Each MSA1510i is shipped with firmware preinstalled on the controller.

However, in between manufacturing cycles, updated firmware may be placed on the

MSA1510i web site: 

http://h18006.www.1.hp.com/products/storageworks/msa1510i.

 HP recommends checking the Web, and if a newer version of firmware is available,

download and install this latest firmware release.

Содержание StorageWorks MSA1510i

Страница 1: ...sk _______________________________ Storage Management Utility access ______________ _______________ Redundant MSA1510i controller for multipathing _______ Redundant MSA1510i 2 Port Ethernet iSCSI module for multipathing ____ Storage Enclosures Quantity MSA20 _______ MSA30 _______ Category 5e or better Ethernet cables SCSI cables 2 2 2 2 2 Pre To ensure co system in an Adequate Front of Back of Ade...

Страница 2: ...rt for the CLI 6 LCD panel push buttons 3 Controller A active controller 7 Power standby button 4 Status lights LEDs Rear features 1 2 Port Ethernet iSCSI module 5 SCSI I O module bus 0 2 System information panel 6 A C power connectors 3 Fan modules 7 Power supply modules 4 Redundant 2 Port Ethernet module blank 8 Additional SCSI I O module blanks 1 2 3 4 5 6 7 15221 1 2 4 3 5 6 7 8 15222 5 5 5 5 ...

Страница 3: ... displayed on the controller Press to copy the firmware from one controller to the other so that the same firmware version is installed on the controllers 4 Press the and LCD panel message buttons on the front of each MSA1510i controller and look for the following messages MSA1510i Startup Complete IP Address ip address Array controller firmware ver version 5 Record the MSA1510i controller managem...

Страница 4: ...igned to the MSA1510i management port 2 When prompted enter the following default access permissions Username root Password root NOTE NOTE NOTE NOTE NOTE When prompted change these defaults to user defined values 3 When the utility opens Click OK to use the wizard Click Cancel to use the SMU 4 In the Welcome window click Next 5 In the Storage Configuration window enter the settings to use The wiza...

Отзывы: