System Unit Specification
Table 5-1: System Unit Specifications
Specification Value
Dimensions
Height
17.5 cm (6.9 in)
Depth
52.1 cm (20.5 in)
Width
48.3 cm (19.0 in)
Weight, no drives installed
22.7 kg (50 lb)
Input power requirements * (US and international)
Rated input voltage
100 to 240 VAC
Rated input frequency
50 to 60 Hz
Rated input current
7.35 A Max
Input power (max)
641 W *
Power supply specifications
Rated steady-state power
499 W
Maximum peak power
681 W
Heat dissipation (max) *
2187 Btu/hr *
Acoustic noise (LWAdc bels and LpAm dBA)
Idle
<6.9 and 53
Fixed disk (random writes)
<7.3 and 54
Temperature range
Operating
10
°
to 35
°
C (50
°
to 95
°
F)
[derated 1
°
C per 304.8 m (1.8°F per 1000 ft) of
elevation to 3,048 m (10,000 ft)]
Shipping
-30
°
to 50
°
C (-22
°
to 122
°
F)
*
Input power and heat dissipation specifications are maximum values and apply to worst-case
conditions at a full-rated power supply load. The power/heat dissipation for your installation varies
depending on the equipment configuration.