Maintenance and Troubleshooting
99
ESL E-Series Tape Library User’s Guide
Verifying SCSI bus configuration
Items to check include:
■
Termination — Problems with termination can cause intermittent or hard
failures. A SCSI bus must be terminated on both ends. Termination problems
are common when both narrow and wide devices are on the same bus.
■
Bus Type — On an LVD SCSI bus, SE and LVD devices can be connected to
the same bus. However, if one SE device is detected during power on,
communication to all devices converts to SE mode.
■
Device ID — Each device on a SCSI bus must have a unique ID. Verify
configured IDs are not in use by other devices on the same SCSI bus.
■
Cabling — Check SCSI cables to verify they are functional. SCSI rules for
total length, distance between devices, and stub length must be followed.
Connections should also be checked and reseated if necessary.
■
SCSI Devices — Verify that the SCSI devices on a particular SCSI bus can be
seen in the Configuration Menu of the FC interface controller. If the FC
interface controller cannot see the devices, verify SCSI configuration, cabling,
and termination.
Verifying FC port connection
If SCSI devices are recognized on the SCSI buses, but do not appear to the FC
host, it may be that the FC link is not properly established. Most hubs and
switches have link indicators showing link status. When the FC interface
controller is connected and powered on, this link indicator should be solid. If it is
not, check the cabling or connections.
One method of verifying link integrity when connected to a functional host,
involves disconnecting and then reconnecting the FC cable. This procedure should
cause momentary activity of this indicator as the link reinitializes.
Additionally, verify that the cable type of the FC interface controller and the
attached hub, HBA, or switch is of corresponding types. When using optical
media, verify that the attached device is using non-OFC type optical devices.
Содержание StorageWorks ESL E-Series
Страница 8: ...Contents 8 ESL E Series Tape Library User s Guide ...
Страница 16: ...About this Guide 16 ESL E Series Tape Library User s Guide ...
Страница 46: ...Library Overview 46 ESL E Series Tape Library User s Guide ...
Страница 106: ...Maintenance and Troubleshooting 106 ESL E Series Tape Library User s Guide ...
Страница 112: ...Library Characteristics 112 ESL E Series Tape Library User s Guide ...
Страница 130: ...Regulatory Statements 130 ESL E Series Tape Library User s Guide BSMI statement ...
Страница 131: ...Regulatory Statements 131 ESL E Series Tape Library User s Guide Japan statement VCCI ...
Страница 132: ...Regulatory Statements 132 ESL E Series Tape Library User s Guide Japan statement AC power cords ...
Страница 178: ...Event Reporting 178 ESL E Series Tape Library User s Guide ...
Страница 184: ...Glossary 184 ESL E Series Tape Library User s Guide ...