Event Codes
163
Edge Switch 2/12 Service Manual
Table 60: Event Code 507
Message:
Loopback diagnostics port failure.
Severity:
Informational.
Explanation:
A loopback diagnostic test detected a Fibre Channel port failure.
Action:
No action required. An event code
506
is generated if this diagnostic failure results
in a hard port failure.
Event Data:
Byte
0
= port number (
00
through
11
).
Byte
1
= engineering reason code.
Bytes
4
through
7
= elapsed millisecond tick count.
Bytes
8
through
11
= reason code specific.
Byte
12
= test type.
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
Table 61: Event Code 508
Message:
Fibre Channel port anomaly detected.
Severity:
Informational.
Explanation:
The switch detected a deviation in the normal operating mode or status of the
indicated Fibre Channel port.
Action:
No action required. An event code
506
is generated if this anomaly results in a
hard port failure.
Event Data:
Byte
0
= port number (
00
through
11
).
Byte
1
= anomaly reason code.
Bytes
4
through
7
= elapsed millisecond tick count.
Bytes
8
and
9
= high-availability error callout #1.
Bytes
10
and
11
= high-availability error callout #2.
Byte
12
= detecting port.
Byte
13
= connected port.
Bytes
16
and
17
= high-availability error callout #3.
Bytes
18
and
19
= high-availability error callout #4.
Содержание StorageWorks Edge Switch 2/12
Страница 16: ...About this Guide 16 Edge Switch 2 12 Service Manual ...
Страница 124: ...Repair Information 124 Edge Switch 2 12 Service Manual ...
Страница 132: ...Illustrated Parts Breakdown 132 Edge Switch 2 12 Service Manual ...
Страница 172: ...Event Codes 172 Edge Switch 2 12 Service Manual ...