Repair Information
102
Edge Switch 2/12 Service Manual
Internal Loopback Test
To perform an internal loopback at the EWS interface:
1. Notify the customer that a disruptive internal loopback test is to be performed.
Ensure the customer’s system administrator quiesces Fibre Channel frame
traffic through the port and sets the attached device offline.
Note:
An SFP optical transceiver must be installed in the port during the test. A device
can remain connected during the test.
2. When the EWS interface opens, the View panel and Switch page appear as
the default. At the View panel, select the Operations option at the left side of
the panel. The Operations panel opens with the Switch page displayed.
3. Click the Port and Diagnostics tabs. The Port page displays with the
Diagnostics tab selected (
Figure 20: Operations panel (Port page with Diagnostics tab)
4. Type the port number to be tested in the Targeted Port Number field.
5. At the Diagnostics Test list box, select the Internal Loopback option.