FRU Removal and Replacement
228
Figure 73: CTP card removal and replacement
6. Pull the CTP card from its card track and remove it from the director chassis.
Place the card in an antistatic bag to provide ESD protection.
Replacing the CTP Card
To replace a redundant CTP card:
1. Wait approximately 20 seconds after removal of the failed CTP card to begin
this replacement procedure.
2. Remove the replacement card from its protective antistatic bag.
3. Hold the card by its stiffener and insert it in the chassis card track, as shown in
. The label identifying the card should be at the top. Verify the card
is aligned in the card tracks, then slide it forward until it makes contact with
the backplane.
1
Torque tool
2
CTP card
2
1