Diagnostics
144
7. Set both directors online (“
Did the operating parameter change solve the problem and did both directors join
through the ISL to form a fabric?
NO
YES
↓
The directors, associated ISL, and multi-switch fabric are operational.
Exit MAP.
Contact the next level of support. Exit MAP.
15
A director E_Port segmented because two fabric elements had duplicate domain
IDs.
1. Work with the system administrator to determine the desired domain ID
(1 through 31 inclusive) for each director.
2. Notify the customer that both directors will set offline. Ensure the system
administrator quiesces Fibre Channel frame traffic through the directors and
sets attached devices offline.
3. Set both directors offline (“
4. At the Hardware View for the first director reporting the problem, choose
Configure > Operating Parameters > Switch Parameters. The Configure
Switch Parameters dialog box displays, as shown in
Figure 36: Configure Switch Parameters dialog box
5. Type the customer-determined preferred domain ID value, then click
Activate.
6. Repeat
step 4
and
at the Hardware View for the director attached to
the segmented E_Port (second director). Use a different preferred domain ID
value.
7. Set both directors online (“
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...