Diagnostics
126
2. At the Hardware View, choose Configure > Operating
Parameters > Fabric Parameters. The Configure Fabric Parameters dialog
box displays, as shown in
Figure 29: Configure Fabric Parameters dialog box
3. Choose the operating mode as follows:
■
Choose Open Fabric 1.0 from the Interop Mode list box.
■
Choose Homogeneous from the Interop Mode list box.
4. Click Activate to save the selection and close the window.
Did configuring the Management Style solve the problem?
NO
YES
↓
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
22
A loopback plug is connected to the port and there is no diagnostic test running. Is
a loopback plug in the port receptacle?
YES
NO
↓
Contact the next level of support. Exit MAP.
23
Remove the loopback plug from the port receptacle. If directed by the customer,
connect a fiber optic jumper cable attaching a device to the director.
■
If the port is operational and a device is not attached, both LEDs adjacent to
the port extinguish and the port state is No Light.
Содержание StorageWorks 2/140 - Director Switch