Recommended action
Status of hardware
LED color
LED name
Verify that the diagnostic tests are
not running. Re-enable the port us-
ing the
portenable
command.
Receiving light or carrier, but
not online
Slow blinking amber
(2 seconds)
Check the management interface
and the error log for details on the
cause of the failure. Contact HP
technical support, if necessary.
Port failure
Fast blinking amber
(1/2 second)
No action required.
Online
Steady green
No action required.
Online but segmented (loopback
cable or incompatible switch)
Slow blinking green
(2 seconds)
No action required.
Internal loopback (diagnostic)
Fast blinking green
(1/2 second)
No action required.
Online; frames flowing through
port
Flickering green
Nonport side LED activity for the FCoE Converged Network
Switch
shows the LEDs on the nonport side of the switch. See
on page 21 for power
supply and fan assembly locations.
4. Fan assembly #2 status LED
1. Power supply #2 status LED
5. Fan assembly #1 status LED
2. Power supply #1 status LED
3. Fan assembly #3 status LED
Figure 32 Nonport side LEDs on the FCoE Converged Network Switch
.