ADU Error Messages
HP Servers Troubleshooting Guide
D-25
HP CONFIDENTIAL
Writer: Ted Weiman File Name: k-appd ADU Error Messages.doc
Codename: Generic TSG Part Number: 161759-007 Last Saved On: 11/19/02 9:53 AM
Table D-1: Array Diagnostic Utility (ADU) Error Messages
continued
Message Description
Recommended
Action
Write memory error
Data can not be written to the
cache memory. This typically
means that a parity error was
detected while writing data to
the cache. This can be caused
by an incomplete connection
between the cache and the
controller. This is not a data
loss circumstance.
With the system powered
down, be sure that the cache
board is fully connected to the
controller.
Wrong Accelerator
This may mean that the board
was replaced in the wrong slot
or was placed in a system
previously configured with
another board type. Included
with this message is a
message indicating (1) the
type of adapter sensed by
ADU, and (2) the type of
adapter last configured in
EISA nonvolatile RAM.
Check the diagnosis screen for
other error messages. Run the
server setup utility to update
the system configuration.