background image

HP Director Blade Installation
Instructions

© Copyright 2011–2012 Hewlett-Packard Development Company, L.P.
Printed in the US

*5697-2056*

Published: June 2012
Edition: 6

Overview

Use these installation instructions if you have purchased
one of the optional director blades listed in

Table 1 (page 1)

. Install the blades in compatible

director models only.

NOTE:

This document refers to blades by their

short names.

Table 1 Director blades

Compatible HP director

models

Part

number

Short name

(imprinted

on blade)

Model

SN8000B 8-Slot SAN
Backbone Director,

QW940A

FC8-32E

HP SN8000B
8Gb 32-port

SN8000B 4-Slot SAN
Director

Enhanced Fibre
Channel Blade

SN8000B 8-Slot SAN
Backbone Director,

QW941A

FC8-48E

HP SN8000B
8Gb 48-port

SN8000B 4-Slot SAN
Director

Enhanced Fibre
Channel Blade

SN8000B 8-Slot SAN
Backbone Director,

QK713A

QK713B

FC16-32

HP SN8000B
16Gb 32-port
Fibre Channel
Blade

SN8000B 4-Slot SAN
Director

SN8000B 8-Slot SAN
Backbone Director,

QK714A

QK714B

FC16-48

HP SN8000B
16Gb 48-port
Fibre Channel
Blade

SN8000B 4-Slot SAN
Director

DC SAN Backbone

nl

AP866A

AP866B

FCOE10-24

HP DC SAN
Director Switch
10/24 FCoE
blade

nl

Director,

nl

DC04 SAN Director

option

DC SAN Backbone

nl

AP865A

AP865B

FX8-24

HP DC SAN
Director Switch

nl

Multi-protocol

nl

Director,

nl

DC04 SAN Director,

nl

Extension blade
option

SN8000B 8-Slot SAN
Backbone Director,
SN8000B 4-Slot SAN
Director

DC SAN Backbone
Director,

nl

AR945A

AR945B

FS8-18

HP DC SAN

nl

Director

nl

Encryption
blade

DC04 SAN Director,

nl

SN8000B 8-Slot SAN
Backbone Director,
SN8000B 4-Slot SAN
Director

2/128 SAN Director,
4/256 SAN Director

A7990A

A7990B

FC4-16

HP SAN
Director

nl

16-port 4Gb FC
blade

Page 1

Содержание SN8000B

Страница 1: ...Slot SAN Director Enhanced Fibre Channel Blade SN8000B 8 Slot SAN Backbone Director QK71 3A QK71 3B FC16 32 HP SN8000B 16Gb 32 port Fibre Channel Blade SN8000B 4 Slot SAN Director SN8000B 8 Slot SAN Backbone Director QK71 4A QK71 4B FC16 48 HP SN8000B 16Gb 48 port Fibre Channel Blade SN8000B 4 Slot SAN Director DC SAN Backbone nl AP866A AP866B FCOE10 24 HP DC SAN Director Switch 10 24 FCoE blade n...

Страница 2: ...B FC8 64 HP DC SAN Director nl 64 port 8Gb Fibre Channel Blade Director nl DC04 SAN Director nl SN8000B 8 Slot SAN Backbone Director SN8000B 4 Slot SAN Director 4 256 SAN Director DC SAN Backbone Director nl AK86 1A AK861B FC10 6 HP SAN Director nl 6 port 10Gb FC blade DC04 SAN Director 4 256 SAN Director AG67 1A AG671B FC4 16IP HP B series iSCSI nl Director blade 4 256 SAN Director nl AG46 1A AG4...

Страница 3: ...8 48E 2 Status LED 1 Power LED 4 FC ports 0 23 3 FC ports 24 47 FC16 32 components Figure 3 FC16 32 2 FC ports 8 15 1 Power LED 4 Port status LED 3 FC ports 0 7 6 Port and trunking group map 5 FC ports 24 31 7 FC ports 16 23 Page 3 ...

Страница 4: ...components Figure 4 FC16 48 2 FC ports 0 23 1 Power LED 4 FC ports 24 47 3 Status LED FCOE10 24 components Figure 5 FCOE10 24 2 10 GbE FCoE ports 0 1 1 1 Power LED 4 10 GbE FCoE ports 12 23 3 Status LED Page 4 ...

Страница 5: ...FX8 24 2 1 GbE ports 0 3 1 Power LED 4 FC ports 0 5 3 10 GbE ports 0 1 6 1 GbE ports 4 9 5 Status LED 7 FC ports 6 1 1 FS8 18 components Figure 7 FS8 18 2 Status LED 1 Power LED 4 Port status LED 3 FC port 5 FC ports 0 15 Page 5 ...

Страница 6: ...ed LED 3 FC Port 6 FC ports 0 15 5 Port status LED FC4 32 components Figure 9 FC4 32 2 Status LED 1 Power LED 4 Port speed LED left port 3 FC Port 6 Port speed LED right port 5 Port status LED left port 8 FC ports 16 31 7 Port status LED right port 9 FC ports 0 15 Page 6 ...

Страница 7: ...ts Figure 10 FC4 48 2 Status LED 1 Power LED 4 Port status LED 3 FC Port 6 FC ports 0 23 5 FC ports 24 47 FC8 16 components Figure 1 1 FC8 16 2 Status LED 1 Power LED 4 Port status LED 3 FC Port 5 FC ports 0 15 Page 7 ...

Страница 8: ...e 12 FC8 32 2 Status LED 1 Power LED 4 Port status LED 3 FC Port 6 FC ports 0 15 5 FC ports 16 31 FC8 48 components Figure 13 FC8 48 2 Status LED 1 Power LED 4 Port status LED 3 FC Port 6 FC ports 0 23 5 FC ports 24 47 Page 8 ...

Страница 9: ...D 1 Status LED 4 Port status LED 3 FC Port 6 FC Port 5 FC Port 8 FC ports 0 31 7 FC ports 32 63 NOTE FC8 64 supports mini SFPs mSFPs only FC10 6 components Figure 15 FC10 6 2 Status LED 1 Power LED 4 Port status LED 3 FC port 5 FC ports 0 5 Page 9 ...

Страница 10: ...6 FC4 16IP 2 Status LED 1 Power LED 4 Port status LED 3 FC Port 6 GbE ports 0 7 5 FC ports 0 7 FR4 18i components Figure 17 FR4 18i blade 2 Status LED 1 Power LED 4 Port status LED 3 FC Port 6 FC ports 0 15 5 GbE ports 0 1 Page 10 ...

Страница 11: ...Removing the filler panel Remove the filler panel if installed There are three filler panel types Figure 18 page 11 CAUTION Remove a filler panel only when installing or replacing a Director blade All slots that are not occupied by a Director blade require a filler panel to ensure cooling of the chassis and protection from dust To remove a filler panel with a handle 1 Unscrew the two captive screw...

Страница 12: ...or Install the blades in slots 1 through 4 and 9 through 12 For the HP SN8000B 4 Slot SAN Director Install the blades in slots 1 and 2 and slots 7 and 8 3 Orient the blade so that the ports face outward away from the slot and the flat noncomponent side is on the left 4 Proceed to Step 5 if the blade you are installing uses ejectors only See Determining the ejector type page 11 For blades with both...

Страница 13: ...7 Install the transceivers and cables For more information This document provides initial setup and configuration procedures only For comprehensive configuration procedures including those for mixed blade configurations see the following HP B series SN8000B 8 Slot SAN Backbone Director Switch Hardware Reference Guide HP HP B series SN8000B 4 Slot SAN Director Switch Hardware Reference Guide HP Sto...

Отзывы: