background image

7

Shertech Operating Instructions, Performance, 
Specifications and Parts Manual

Bronze Models GCBN2V, GCBN3V, GCBN22V and GCBN33V
Cast Iron Models GCCV2V, GCCV3V, GCCV22V and GCCV33V

Form L-4083 (1/06)

6. Be certain all suction piping connec-

tions are airtight.

NOTE: 

Assure airtight pipe connections

with the use of a pipe joint sealant.

DISCHARGE

1. Attach discharge piping to the 

discharge outlet.

Support  pump and
piping during assem-

bly and after installation. Failure to do so may
cause piping to break, pump to fail, motor
bearing failures, etc. All of which can result 
in property damage and/or personal injury.

NOTE: 

Should the pump need to be

self-draining, the pump head should be
mounted in the vertical position with
the suction port facing down.  When
pumping high viscosity fluids, the 
vertical position can be used with the
suction port facing up and the pump
mounted under the source.  Increasing
the suction pipe size and eliminating
bends and elbows also assists in pump-
ing high viscosity fluids. Max. viscosity is
500 SSU at 1725 RPM.

2. If a shut-off valve or handgun is

required in discharge line, provide 
a pressure relief valve for pump 
protection.

Shutting off 

discharge without

providing pressure relief can cause extreme
over-pressure which can result in pump
and/or motor failure. Do not exceed 100 PSI
pump or system pressure.

3. Operation under shut-off discharge

conditions will overheat and 
damage pump. 

NOTE:

Globe valve or other restrictive

valves should not be used as shut-off
mechanism as they are restrictive in
nature and will seriously affect pump
performance.

4. After all piping and controls (not

supplied with unit) have been
installed, unit is ready for operation.

Operation

Do not run pump dry,
as permanent damage

to the pump gears, seal, and bearings will
result. Suction pressure should never be
greater than the discharge pressure.

1. All pumps must be primed before

start-up. Never operate a pump
unless it is secured to a solid 
foundation.

2. Gear pumps are built to very close

tolerances and this tolerance must
not be altered. The liquids must,
therefore, be free of all abrasives.
Sand, silt, wettable powders, etc.
must be avoided. 

NOTE: 

Cast iron pumps are for oil-based

fluids only.

3. When pumping a more viscous

(beyond 500 SSU) liquid, a slower
speed, a larger pipe size pump, 
and possibly a larger motor should
be selected. 

NOTE:

See performance chart for Max.

Torque.

4. Recheck motor rotation. Proper

motor/pump rotation is clockwise
(CW) looking at the motor shaft 
(See Figure 3).

5. On all models, the pressure relief

valve is always on discharge side
(See Figure 3).

PRESSURE RELIEF VALVE

6. Standard model rotary gear pumps

are supplied with a built-in pressure
relief valve. The valve may be adjust-
ed and used to set system operating
pressure, or used as a system relief
valve to prevent pump and motor
damage that can occur when dis-
charge line is closed off. This relief
valve is not factory set. Extended
operation (over one minute) under
shut-off conditions could cause pump
to overheat, leak, and damage itself.

7. To increase the relief valve pressure

setting, remove protective cap,

loosen lock nut, then turn the set
screw (Figure 4 & 7, Ref. No. 18) in
(clockwise). Turning the set screw
out (counterclockwise) will reduce
the pressure setting. When desired
pressure is achieved, tighten lock
nut and reinstall protective cap.

8. The pressure relief valve can be 

converted to an external relief. This
will allow the relief to dump back 
to tank and allow longer periods of
relief without pump damage.
However, this is not a full-line relief
valve, and in cases where frequent
extended relief valve operation is
anticipated, a full-line size relief
valve should be piped in the dis-
charge line and connected either
back to the tank or well down-
stream of the pump suction inlet.

9. To convert the relief valve to exter-

nal relief, remove the 1/4 NPT pipe
plug from the pump cover (Figure 5
& 7, Ref. No. 13) and discard. This
plug is next to the relief valve. In
the bottom of the 1/4 NPT hole,
there is a second drilled and tapped 

Figure 4 - Pressure 
Relief Valve Adjustment

Protective 

cap

Adjust pressure
relief valve screw

Loosen 
lock nut

Figure 5 - External Bypass Installation

Optional
external
bypass plug

Remove and
discard plug

Содержание Shertech GCBN22V

Страница 1: ...or use with oil based fluids Not to be used with water based fluids Pumps include steel spur gears with steel shafts and cast iron shaft support standard pressure relief valves that can be ported internally or externally and a Viton mechanical carbon ceramic faced seal with temperature range of 32 to 280 F Wet end parts are constructed from cast iron steel stainless steel 302 303 and or 18 8 carbo...

Страница 2: ...HP 3 1 2 HP V Pressure Relief Valve Standard 1st 2nd 3rd 4th 5th 6th Mounting Material Sealing Gear Size Ports AC Motor Options NOTE Not all order code combinations configurations are standard models available from the manufacturer Custom model configurations may require ordering standard components and or optional parts that will need to be assembled by the customer Manufacturer reserves the righ...

Страница 3: ... by 10 Don t use water with Cast Iron Pump performance when pump is new As pump wears the performance will decrease NPT inlet and outlet in inches Suction lift requires wetted gears and primed seal chamber Motor not provided NOTES Pumps with motors are HP rated to handle up to 500 SSU at 100 PSI and specific gravity of 1 0 Max PSI 100 Max Viscosity 500 SSU Max RPM 1725 Max Specific Gravity 1 1 at ...

Страница 4: ...5 3 8 CI CRS CRS CI CRS SS Viton Mech 22 3 Models without Motors GCBN2V 48Y 1725 1 4 BZ BZ 303 SS CG BR SS Buna Mech 4 3 GCBN3V 48Y 1725 3 8 BZ BZ 303 SS CG BR SS Buna Mech 4 8 GCCV2V 48Y 1725 1 4 CI CRS CRS CI CRS SS Viton Mech 4 0 GCCV3V 48Y 1725 3 8 CI CRS CRS CI CRS SS Viton Mech 4 3 BZ Bronze BR Brass CG Carbon Graphite CI Cast Iron CRS Cold Rolled Steel ODP Open Drip Proof Motor not provided...

Страница 5: ...3 4 11 16 35 8 21 2 GCBN33V GCCV33V 3 8 21 4 27 16 3 7 89 16 23 4 55 8 41 4 53 4 11 16 35 8 21 2 Models without Motors GCBN2V GCCV2V 1 4 129 32 3 69 16 35 8 21 2 GCBN3V GCCV3V 3 8 21 4 3 7 35 8 21 2 NPT inlet and outlet in inches This dimension may vary due to motor manufacturer s specifications NOTE Dimensions have a tolerance of or 1 8 Manufacturer reserves the right to change dimensions without...

Страница 6: ... Locate the pump as close to the liquid source as possible making the suction line as short and direct as possible Ambient temperature around motor should not exceed 104 F 40 C 2 Open drip proof motors are designed to be used in clean dry locations with access to an adequate supply of cooling air 3 For outdoor installations the motor must be protected by a cover that does not block air flow to and...

Страница 7: ...s and this tolerance must not be altered The liquids must therefore be free of all abrasives Sand silt wettable powders etc must be avoided NOTE Cast iron pumps are for oil based fluids only 3 When pumping a more viscous beyond 500 SSU liquid a slower speed a larger pipe size pump and possibly a larger motor should be selected NOTE See performance chart for Max Torque 4 Recheck motor rotation Prop...

Страница 8: ... is a difficult motor pump to repair therefore only qualified electricians or service techni cians should attempt to repair this unit Improper repair and or assembly can cause problems with the electric motor used with this unit See General Safety Information Retighten the V band clamp screw as necessary Use Loctite or similar thread sealant if screw keeps coming loose Rotary gear pumps must be dr...

Страница 9: ...d Do not run pump dry as permanent damage to the pump gears seal and bearings will result Suction pressure should never be greater than the discharge pressure Mechanical Seal Replacement Refer to Figures 6 7 for parts identification 1 Remove pump from motor if not already done 2 Remove snap ring Ref No 12 Pry out seal seat Ref No 11 Pull mechanical seal Ref No 10 off shaft See Assembly 3 through 5...

Страница 10: ...t the pump head be replaced Note that seals and o rings used in each material type are interchangeable The Viton components from the cast iron models can be used in the bronze and the Buna in the bronze models can be used in the cast iron models Figure 7 Repair Parts Illustration Please provide following information Model number Serial number if any Part description and number as shown in parts li...

Страница 11: ...A NA NA NA NA NA 1 14 External Bypass Relief Plug NA NA NA NA NA NA NA NA 1 15 Relief Valve Cap NA NA NA NA NA NA NA NA 1 16 Washer NA NA NA NA NA NA NA NA 1 17 Hex Nut NA NA NA NA NA NA NA NA 1 18 Set Screw 18 8 SS NA NA NA NA NA NA NA NA 1 19 O ring NA NA NA NA NA NA NA NA 1 20 O ring Retainer NA NA NA NA NA NA NA NA 1 21 O ring NA NA NA NA NA NA NA NA 1 22 Spring 302 SS NA NA NA NA NA NA NA NA ...

Страница 12: ...cals must be labeled before being shipped to Hypro for service or warranty consideration Hypro reserves the right to request a Material Safety Data sheet from the Purchaser for any pump or product Hypro deems necessary Hypro reserves the right to disposition as scrap pumps or products returned without authorization and or which contain unknown substances or to charge for any and all costs incurred...