background image

Low Voltage NA/JPN model

Low Voltage NA/JPN model

Low Voltage NA/JPN model

Low Voltage NA/JPN model
(2880VA / 2700 Watt)

(2880VA / 2700 Watt)

(2880VA / 2700 Watt)

(2880VA / 2700 Watt)

 

 

 

Load (Percent

Load (Percent

Load (Percent

Load (Percent

*

))))

Estimates battery runtime

Estimates battery runtime

Estimates battery runtime

Estimates battery runtime

(Minutes)

(Minutes)

(Minutes)

(Minutes)

With One Extended Runtime

With One Extended Runtime

With One Extended Runtime

With One Extended Runtime

Module

Module

Module

Module (Minutes)

 (Minutes)

 (Minutes)

 (Minutes)

With Two Extended Runtime

With Two Extended Runtime

With Two Extended Runtime

With Two Extended Runtime

Modules

Modules

Modules

Modules (Minutes)

 (Minutes)

 (Minutes)

 (Minutes)

540W (20%)

540W (20%)

540W (20%)

540W (20%)

45

45

45

45

142

142

142

142

256

256

256

256

1350W (50%)

1350W (50%)

1350W (50%)

1350W (50%)

15

15

15

15

55

55

55

55

99

99

99

99

2160W (80%)

2160W (80%)

2160W (80%)

2160W (80%)

7

7

7

7

34

34

34

34

60

60

60

60

2700W (100%)

2700W (100%)

2700W (100%)

2700W (100%)

5

5

5

5

26

26

26

26

47

47

47

47

NOTE:

NOTE:

NOTE:

NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions.

 

 

 

 

High Voltage NA/JPN and Int'l model

High Voltage NA/JPN and Int'l model

High Voltage NA/JPN and Int'l model

High Voltage NA/JPN and Int'l model
(3300VA / 3000 Watt)

(3300VA / 3000 Watt)

(3300VA / 3000 Watt)

(3300VA / 3000 Watt)

 

 

 

Load (Percent

Load (Percent

Load (Percent

Load (Percent

*

))))

Estimated battery runtime

Estimated battery runtime

Estimated battery runtime

Estimated battery runtime

(Minutes)

(Minutes)

(Minutes)

(Minutes)

With One Extended Runtime

With One Extended Runtime

With One Extended Runtime

With One Extended Runtime

Module

Module

Module

Module (Minutes)

 (Minutes)

 (Minutes)

 (Minutes)

With Two Extended Runtime

With Two Extended Runtime

With Two Extended Runtime

With Two Extended Runtime

Modules

Modules

Modules

Modules (Minutes)

 (Minutes)

 (Minutes)

 (Minutes)

600W (20%)

600W (20%)

600W (20%)

600W (20%)

40

40

40

40

125

125

125

125

225

225

225

225

1500W (50%)

1500W (50%)

1500W (50%)

1500W (50%)

12

12

12

12

50

50

50

50

99

99

99

99

2400W (80%)

2400W (80%)

2400W (80%)

2400W (80%)

6

6

6

6

30

30

30

30

60

60

60

60

3000W (100%)

3000W (100%)

3000W (100%)

3000W (100%)

4

4

4

4

24

24

24

24

47

47

47

47

NOTE:

NOTE:

NOTE:

NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions.

QuickSpecs

HP R/T3000 G2 Uninterruptible Power System (UPS)

HP R/T3000 G2 Uninterruptible Power System (UPS)

HP R/T3000 G2 Uninterruptible Power System (UPS)

HP R/T3000 G2 Uninterruptible Power System (UPS)

Estimated Backup Times Chart (Minutes)

DA - 14058   Worldwide — Version 2 — July 20, 2011

Page 11

Содержание R/T3000 G2

Страница 1: ... In addition Extended Runtime Modules ERM are available to increase battery run time during a power outage ERMs can be used in both rack mount and tower configuration with the HP R T3000 G2UPS Robust and Flexible UPS management is provided by HP s New Power Protector UPS Management software R T3000 Rackmount UPS configuration R T3000 Rackmount UPS configuration R T3000 Rackmount UPS configuration ...

Страница 2: ...in Tower UPS configuration Models Models Models Models HP R T3000 G2 2U L530 Low Voltage NA JP Uninterruptible Power System AF466A HP R T3000 G2 2U L620 High Voltage NA JP Uninterruptible Power System AF467A HP R T3000 G2 2U Detachable Cord High Voltage INTL Uninterruptible Power System AF468A QuickSpecs HP R T3000 G2 Uninterruptible Power System UPS HP R T3000 G2 Uninterruptible Power System UPS ...

Страница 3: ...ded Runtime with Extended Runtime with Extended Runtime Modules Modules Modules Modules The Extended Runtime Modules are external battery modules that occupy 2U 3 5 inches of rack space each The HP UPS R T3000 G2 supports up to two Extended Runtime Modules ERM in either rack mount or tower configuration which extend your overall battery runtime Lower Cost of Ownership Lower Cost of Ownership Lower...

Страница 4: ...LED and switch membrane integrated into the front panel with power controls and status and load indicators for easy visibility HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel HP R T3000 UPS Front Panel 1 Dual function LED Self Test and load indicator 10 load 7 Power on button 2 Dual function LED Battery fault and Load Indicator 25 load 8 Power off button 3 Dual fun...

Страница 5: ...wn connected server and server options HP Quality HP Quality HP Quality HP Quality HP s hardware qualification is the toughest in the industry Extensive evaluation testing product improvement and an unsurpassed warranty guarantee the highest level of system protection electrical performance product quality and compatibility Compatibility Compatibility Compatibility Compatibility Compatible with al...

Страница 6: ... Related Services Related Services Related Services 3 Year HP 6 hour Hardware Support Onsite Call to Repair Service 3 Year HP 6 hour Hardware Support Onsite Call to Repair Service 3 Year HP 6 hour Hardware Support Onsite Call to Repair Service 3 Year HP 6 hour Hardware Support Onsite Call to Repair Service Provides an IT manager with a team of support specialists who will quickly begin troubleshoo...

Страница 7: ...he technical data sheet are not eligible for the defective media retention service feature option For more information For more information For more information For more information To learn more on services for HP ESSN Options please contact your HP sales representative or HP Authorized Channel Partner Or visit http www hp com services proliant or www hp com services bladesystem QuickSpecs HP R T...

Страница 8: ...f the UPS from anywhere and at anytime via a standard web browser NOTE NOTE NOTE NOTE For more information on the UPS Network Module please see www hp com go hpunm Extended Runtime Module Extended Runtime Module Extended Runtime Module Extended Runtime Module ERM ERM ERM ERM The UPS R T3000 G2 supports up to two Extended Runtime Modules Each module is a 2U 3 5 inches rack mountable battery module ...

Страница 9: ... Network Module AF465A HP Care Pack HP Care Pack HP Care Pack HP Care Pack HP Install Universal Power Supply 3KVA to Below 6KVA Service U4693E QuickSpecs HP R T3000 G2 Uninterruptible Power System UPS HP R T3000 G2 Uninterruptible Power System UPS HP R T3000 G2 Uninterruptible Power System UPS HP R T3000 G2 Uninterruptible Power System UPS Related Options DA 14058 Worldwide Version 2 July 20 2011 ...

Страница 10: ... has 7x C13 outlets and plugs into a C 19 on the rear of the UPS AF468A International 220 230 240 3300 3000 Detachable IEC C 20 inlet plug LS12 3x IEC C13 1x IEC C 19 LS23 3x IEC C13 1x IEC C 19 NOTE NOTE NOTE NOTE Includes one PDU Extension Bar Each Extension Bar has 7x C13 outlets and plugs into a C 19 on the rear of the UPS 1 Factory default setting 2 LS1 Load Segment 1 3 LS2 Load Segment 2 Kit...

Страница 11: ...l model High Voltage NA JPN and Int l model High Voltage NA JPN and Int l model 3300VA 3000 Watt 3300VA 3000 Watt 3300VA 3000 Watt 3300VA 3000 Watt Load Percent Load Percent Load Percent Load Percent Estimated battery runtime Estimated battery runtime Estimated battery runtime Estimated battery runtime Minutes Minutes Minutes Minutes With One Extended Runtime With One Extended Runtime With One Ext...

Страница 12: ...ckup Time Backup Time Backup Time Backup Time See Backup Times Chart Recharge Time Recharge Time Recharge Time Recharge Time 3 hours to 80 usable capacity 48 hours for complete recharge Serial Ports Serial Ports Serial Ports Serial Ports Standard DB 9 and USB ports ships with communication cables Communications Communications Communications Communications Option Slot Option Slot Option Slot Option...

Страница 13: ... for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2011 Hewlett Packard Development Company L P The information contained herein is subject t...

Отзывы: