a.
Press and hold both sides of the connector.
b.
Disconnect the cable from the server.
Dedicated iLO management module
Observe the following rules and limitations when installing an dedicated iLO management port module:
• If a dedicated iLO management port module is installed in the server:
◦ The server can only connect to a network through the dedicated iLO management port module.
◦ The server cannot be accessed through the chassis management module.
• If using the chassis management module iLO ports or the dedicated iLO management port module to
connect to a network, the network must operate at a speed of 1 Gb/s. The server cannot connect to
the network if the network is operating at a speed of 10/100 Mb/s or 10 Gb/s.
For more information about product features, specifications, options, configurations, and compatibility, see
the product QuickSpecs on the
Hewlett Packard Enterprise website
Removing the dedicated iLO management module
Procedure
1.
Back up all server data.
2.
3.
Disconnect all peripheral cables from the server front panel.
4.
Remove the server from the chassis
.
5.
Place the server on a sturdy, level surface.
6.
.
7.
.
8.
Remove the drive cage assembly
.
9.
If installed in slot 10,
10.
Remove the failed dedicated iLO management module.
68
Dedicated iLO management module
Содержание ProLiant XL270d Gen9
Страница 12: ...12 Customer self repair ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...14 Customer self repair ...
Страница 15: ...Customer self repair 15 ...
Страница 118: ... Slot 10 118 Cabling ...
Страница 120: ...PCI riser module signal cabling 4 1 riser signal cable 120 PCI riser module signal cabling ...
Страница 121: ...8 1 riser sideband cable 8 1 riser sideband cable 121 ...