11.
Install the GPU.
a.
Slide the GPU halfway into the server.
b.
Connect the power cable to the GPU.
c.
Install the GPU into the server and tighten the thumbscrew.
12.
Install the side panel.
13.
Install the access panel.
14.
Install the server into the chassis.
15.
Connect all peripheral cables to the server .
16.
Power up the server .
Replacing the failed NVIDIA P4 GPU adapter
NOTE:
The NVIDIA P4 GPU adapter can be installed in slots 1, 2, 5, and 6 only.
Procedure
1.
Back up all server data.
2.
3.
Disconnect all peripheral cables from the server front panel.
4.
Remove the server from the chassis
.
5.
Place the server on a sturdy, level surface.
6.
.
52
Replacing the failed NVIDIA P4 GPU adapter
Содержание ProLiant XL270d Gen9
Страница 12: ...12 Customer self repair ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...14 Customer self repair ...
Страница 15: ...Customer self repair 15 ...
Страница 118: ... Slot 10 118 Cabling ...
Страница 120: ...PCI riser module signal cabling 4 1 riser signal cable 120 PCI riser module signal cabling ...
Страница 121: ...8 1 riser sideband cable 8 1 riser sideband cable 121 ...