![HP ProLiant ML350e Gen8 Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/hp/proliant-ml350e-gen8/proliant-ml350e-gen8_maintenance-and-service-manual_164874063.webp)
Component identification 63
Item
Description
4
Thermal sensor
5
SFF drives (8)
6
Optional drive bay
Front panel LEDs and buttons
Item Description
Status
1
Health LED
Solid green = Normal
Flashing amber = System degraded
Flashing red (1 Hz/cycle per sec) = System critical
Fast-flashing red (4 Hz/cycles per sec) = Power fault*
2
NIC status LED
Solid green = Link to network
Flashing green (1 Hz/cycle per sec) = Network active
Off = No network activity
3
Power On/Standby button
and system power LED
Solid green = System on
Flashing green (1 Hz/cycle per sec) = Performing power on sequence
Solid amber = System in standby
Off = No power present**
* To identify components in a degraded or critical state, see the Systems Insight Display LEDs ("
Front panel LEDs
and buttons
), check iLO/BIOS logs, and reference the server troubleshooting guide.
** Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has
occurred, or the power button cable is disconnected.
Содержание ProLiant ML350e Gen8
Страница 12: ...Customer self repair 12 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 22: ...Illustrated parts catalog 22 ...
Страница 70: ...Component identification 70 LFF drive numbering Four bay four bay LFF drive numbering hot plug only ...
Страница 83: ...Cabling 83 RPS configuration Integrated configuration showing Smart Array controller card installed ...
Страница 84: ...Cabling 84 RPS configuration showing Smart Array controller card installed ...