background image

NOTE:

 Memory configurations listed do not apply to "Factory Integrated Models".

HP ProLiant ML350 G5 Memory Configuration

The HP ProLiant ML350 G5 requires memory interleaving when more than one DIMM is installed. For interleaving, DIMMs
must be configured in identical pairs. The system will not boot properly if multiple DIMMs of varying density or type are
installed in the system.

Standard Memory

All HP ProLiant ML350 G5 models ship with PC2-5300 Fully Buffered DIMMs (DDR2-667).
Entry models include a single 512 MB DIMM (Dual-Core) or two 512MB DIMMs (Quad-Core).
Base models include two 512 MB DIMMs (1 GB total memory).
Factory Integrated Models include the memory capacity of your choice.

Common Memory Configuration

Valid DIMM pair combinations use slots 1/5, slots 2/6, slots 3/7, and slots 4/8. Maximum supported memory is 16 GB for
Dual-Core and 32 GB on Quad-Core models.

NOTE: 

Charts does not represent all possible memory configurations.

 

Memory

Slot

 

1A

2B

3C

4D

5A

6B

7C

8D

Standard

1 GB

512 MB

Empty

Empty

Empty

512 MB

Empty

Empty

Empty

Optional

13 GB

512 MB

2 GB

2 GB

2 GB

512 MB

2 GB

2 GB

2 GB

Maximum

32 GB

4 GB

4 GB

4 GB

4 GB

4 GB

4 GB

4 GB

4 GB

 

Following are memory options available from HP:

 

512MB FBD PC2-5300 1 x 512 MB Kit

413507-B21

1 GB FBD PC2-5300 2 x 512 MB Kit

397409-B21

2 GB FBD PC2-5300 2 x 1 GB Kit

397411-B21

2 GB FBD PC2-5300 2 x 1 GB LP Kit

461826-B21

4 GB FBD PC2-5300 2 x 2 GB Kit

397413-B21

4 GB FBD PC2-5300 2 x 2 GB LP Kit

461828-B21

8 GB FBD PC2-5300 2 x 4 GB Kit

397415-B21

 

 

Online spare memory configuration

FBDIMMs can either be single-rank or dual-rank. Certain FBDIMM configuration requirements are based on these
classifications. A dual-rank FBDIMM is similar to having two separate FBDIMMs, or ranks, on the same module. Although
only a single FBDIMM module, a dual-rank FBDIMM acts as two separate FBDIMMs.

In online spare mode, a single rank of memory acts as the spare memory. For single-rank FBDIMMs, the entire FBDIMM
acts as the spare memory. For a dual-rank FBDIMM, only half of the FBDIMM acts as the spare memory while the other half
is available for operating system and application usage.

Online spare FBDIMM configuration requirements (in addition to general configuration requirements):

When only bank A is being used, it must be fully populated with dual-rank FBDIMMs.
For optimum memory usage, HP recommends all FBDIMMs be the same size with the same HP part number. If
different sized FBDIMMs are used, a portion of the installed memory may not be utilized.

In online spare mode, FBDIMMs must be populated as specified in the following table:

Configuration 1 (Bank A only) is only supported if using bank A, populated with dual-rank FBDIMMs.
After installing FBDIMMs, use RBSU to configure the system for online spare memory support.

Bank A

1A and 5A

Bank B

2B and 6B

Bank C

3C and 7C

Bank D

4D and 8D

QuickSpecs

HP ProLiant ML350 Generation 5

Memory

DA - 12475   Worldwide QuickSpecs — Version 20 — 11/27/2007

Page 34

Содержание ProLiant ML350 Generation 5

Страница 1: ...cess to add 2nd redundant power supply 10 Mouse port 11 Keyboard port 12 Power What s New New Intel s latest Quad Core Xeon 5400 series processors with 12MB 2x6MB L2 cache Base models with Quad Core Xeon 5400 series processors come standard with 2GB system memory At A Glance Building on a tradition of excellence the HP ProLiant family introduces the fifth generation HP ProLiant ML350 server The HP...

Страница 2: ...r optional redundant system fans Management HP Insight Control Environment server management software Integrated Lights Out 2 featuring Integrated Remote Console with KVM over IP performance over shared network access Support for ROM Based Setup Utility RBSU and redundant ROM Systems Insight Manager SmartStart and Automatic Server Recovery 2 ASR 2 HP Power Meter and Power Regulator for ProLiant de...

Страница 3: ...1066 FSB NOTE Available via Configuration To Order only Quad Core Intel Xeon Processor E5430 2 66 GHz 80 Watts 1333 FSB Quad Core Intel Xeon Processor E5420 2 50 GHz 80 Watts 1333 FSB Quad Core Intel Xeon Processor E5410 2 33 GHz 80 Watts 1333 FSB Quad Core Intel Xeon Processor E5320 1 86 GHz 80 Watts 1066 FSB Quad Core Intel Xeon Processor E5310 1 60 GHz 80 Watts 1066 FSB Dual Core Intel Xeon Pro...

Страница 4: ... bit 133MHz PCI X 12 28 20 1 no 3 3 Volt NOTE Bus number listed reflects the default bus assignment Inserting cards with PCI bridges may alter the actual bus assignment number NOTE Slots are enumerated differently based on operating system Microsoft s operating systems enumerate from lowest to highest Device ID by bus starting with the lowest bus NOTE A single PCI Express slot with x8 Bus Speed ca...

Страница 5: ...on regarding USB support http h18004 www1 hp com products servers platforms usb support html Graphics Integrated ATI ES1000 32MB video standard 16 bit color maximum resolution of 1600 x 1200 32 bit color maximum resolution of 1280 x 1024 NOTE Maximum resolution available via iLO 2 remote console is 1280x1024 Form Factor Tower or Rack 5U NOTE Rack models and rack conversion kit support Square or ro...

Страница 6: ...ded with the ProLiant Essentials Rapid Deployment Pack For additional information about the Management Agents and the HP System Management Homepage please visit the management Web site at http www hp com servers manage SmartStart SmartStart simplifies server setup by providing a quick easy way to deploy reliable and consistent server configurations For more information please visit the SmartStart ...

Страница 7: ...or migrating servers between physical or virtual platforms whether migrating to VMware or Microsoft virtual machines SMP Universal allows all of the following Physical to ProLiant Physical to virtual Virtual to virtual Virtual to ProLiant Performance Management Pack offered exclusively through the Insight Control suites a performance management solution that identifies and explains hardware perfor...

Страница 8: ...al Unit ID control Integrated Remote Console ActiveX Control client Dedicated full function shared network connectivity with VLAN Embedded system health Present power consumption Browser command line and scripted access Automatic IP Configuration via DHCP DNS WINS Industry Standard 128 bit Secure Sockets Layer SSL and Secure Shell security SSH Advanced Encryption Standard AES Triple Data Encryptio...

Страница 9: ...om go powercordmatrix UPS and PDU Power Cord Matrix Please see the UPS and PDU cable matrix that lists cable descriptions requirements and specifications for UPS and PDU units http h18004 www1 hp com products servers proliantstorage power protection index html Power Supply 800 Watt CE Mark Compliant Hot Plug Power Supply 1000 Watt high line Optional second Power Supply provides redundant capabilit...

Страница 10: ... ML350 G5 rack kit and an additional option kit from Rack Solutions http www racksolutions com hp Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration customization integration and deployment services for HP servers and storage products Customers can choose how their factory solutions are built tested integrated shipped and deployed Factory Express offers servi...

Страница 11: ...s an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of your business Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime Recommended Service simplify ProLiant solution implementation maintenance and management Support 3 Year 4 ...

Страница 12: ... 80TB LFF SAS 4 50TB LFF SATA Optical Drive One of the following depending on Mode Quad Core 16x DVD ROM standard Dual Core 48x CD ROM standard PCI Express Slots Six expansion slots three PCI Express three PCI X Power Supplies 800 Watt CE mark compliant Hot Plug power supply Optional second power supply provides redundant operation Fans 2 fans ship standard 4 fans total supported does not include ...

Страница 13: ... 480GB SFF SATA Optical Drive One of the following depending on Mode Quad Core 16x DVD ROM standard Dual Core 48x CD ROM standard PCI Express Slots Six expansion slots three PCI Express three PCI X Power Supplies 800 Watt CE mark compliant Hot Plug power supply Optional second power supply provides redundant operation Fans 2 fans ship standard 4 fans total supported does not include power supply o...

Страница 14: ... Six expansion slots one 64 bit 133 MHz PCI X two 64 bit 100 MHz PCI X and three x4 PCI Express with x8 connectors Six USB ports 800W Hot Plug Power Supply Tower Form Factor Keyboard 2 button Mouse SFF 2 5 Drives HP ProLiant ML350G5 SFF SAS SATA Tower CTO Chassis 395570 B21 Includes Embedded NC373i Multifunction Gigabit Server Adapter Integrated Smart Array E200i Controller Eight Hot Plug SFF SAS ...

Страница 15: ...O Kit 435512 L21 HP E5310 ML350G5 FIO Kit 435513 L21 HP X5160 ML350G5 FIO Kit 416891 L21 HP X5150 ML350G5 FIO Kit 416890 L21 HP X5140 ML350G5 FIO Kit 416889 L21 HP X5130 ML350G5 FIO Kit 416888 L21 HP X5120 ML350G5 FIO Kit 416887 L21 HP X5110 ML350G5 FIO Kit 416886 L21 Base Memory 512 MB FBD PC2 5300 1 x 512 MB Kit 413507 B21 1 GB FBD PC2 5300 2 x 512 MB Kit 397409 B21 2 GB FBD PC2 5300 2 x 1 GB Ki...

Страница 16: ...NOTE SAS Controller supporting RAID 0 1 1 0 5 6 337972 B21 Smart Array 642 Controller NOTE U320 Controller 291967 B21 Smart Array 6402 128 Controller NOTE U320 Controller 273915 B21 Smart Array 6404 256 Controller NOTE U320 Controller 273914 B21 64 Bit 133 MHz Single Channel Ultra320 SCSI HBA G2 374654 B21 HP Smart Array 6404 512 FIO CNTRLR 452240 B21 Step 4 Choose Additional Options for Factory I...

Страница 17: ...ical Support and Updates NOTE For additional License Kits please see the QuickSpecs at http h18000 www1 hp com products quickspecs 12631_div 12631_div html 452148 B21 ProLiant Essential RDMA Pack HP ProLiant Essentials RDMA Pack for Embedded Multifunction Gigabit Server Adapters No Media 1 Server License NOTE For additional License Kits please see the QuickSpecs at http h18000 www1 hp com products...

Страница 18: ...ect Pack Integrated Lights Out Select Pack No Media 1 Server License including 1 year of 24x7 Technical Support and Updates NOTE For additional License Kits please see the QuickSpecs at http h18000 www1 hp com products quickspecs 10861_div 10861_div html 452158 B21 Integrated Lights Out Power Management Pack HP iLO Power Management Pack No Media 1 Server License including 1 year of 24x7 Technical ...

Страница 19: ...ocessor 5130 2 0 GHz 65 Watts 1333 FSB 416888 B21 Dual Core Intel Xeon Processor 5120 1 86 GHz 65 Watts 1066 FSB 416887 B21 Dual Core Intel Xeon Processor 5110 1 6 GHz 65 Watts 1066 FSB 416886 B21 Dual Core Intel Xeon Processor 5080 3 73 GHz 130 Watts 1066 FSB 409397 B21 Dual Core Intel Xeon Processor 5060 3 2 GHz 130 Watts 1066 FSB 409401 B21 Dual Core Intel Xeon Processor 5050 3 0 GHz 95 Watts 6...

Страница 20: ...HP 120GB 1 5G SATA 5 4K SFF HDD 431786 B21 HP 60GB 1 5G SATA 5 4K SFF HDD 379306 B21 NOTE SATA hard drives have a 1 year warranty Please see the SATA Hard Drive QuickSpecs for Technical Specifications such as capacity height width interface transfer rate seek time physical configuration and operating temperature http h18000 www1 hp com products quickspecs 11940_div 11940_div html Worldwide 3 5 SAT...

Страница 21: ...drive attach 337972 B21 512MB Battery backed write cache BBWC upgrade NOTE For Smart Array P600 Controller 372538 B21 Smart Array P800 Controller HP Smart Array P800 512 BBWC Controller NOTE Supports external drive attach 381513 B21 NOTE Please see the following QuickSpecs additional information http h18000 www1 hp com products quickspecs 12460_div 12460_div html Smart Array E200 Controller http h...

Страница 22: ..._div html Smart Array 642 http h18000 www1 hp com products quickspecs 12566_div 12566_div html SC11Xe HBA Communications HP NC110T PCI Express Gigabit Server Adapter NOTE Does not support Windows 2000 434905 B21 HP NC360T PCI Express Dual Port Gigabit Server Adapter 412648 B21 HP NC364T PCI Express Quad Port Gigabit Server Adapter NOTE Does not support Windows 2000 435508 B21 HP NC373F PCI Express...

Страница 23: ...Tape Drive Carbonite DW016A HP StorageWorks LTO 3 Ultrium 920 SCSI Internal Tape Drive EH841A HP StorageWorks LTO 3 Ultrium 960 Internal Tape Drive Carbonite Q1538A HP StorageWorks LTO 4 Ultrium 1840 SCSI Internal Tape Drive EH853A NOTE Please see the HP StorageWorks LTO Ultrium Tape Drive QuickSpecs for additional options such as controllers media and other related items http h18006 www1 hp com p...

Страница 24: ...t NOTE 2TB of Disk Storage EH924A NOTE Please see the HP D2D Backup Systems QuickSpecs for additional information http h18000 www1 hp com products quickspecs 12651_div 12651_div html Worldwide Tape Autoloaders HP StorageWorks DAT Autoloader HP StorageWorks DAT 72x10 tape autoloader AE313B HP StorageWorks 1 8 Tape Autoloader HP StorageWorks 1 8 LTO 3 Ultrium 920 G2 Tape Autoloader AH165A HP Storage...

Страница 25: ...920 SAS Drive Library AH561A HP StorageWorks MSL8096 2 LTO 3 Ultrium 960 4GB FC Library AH218A HP StorageWorks MSL8096 2 LTO 3Ultrium 960 SCSI Drive Library AH219A HP StorageWorks MSL8096 2 LTO 4 Ultrium 1840 SCSI Drive Library AJ039A HP StorageWorks MSL8096 2 LTO 4 Ultrium 1840 4GB FC Library AJ040A HP StorageWorks MSL6000 Tape Library LTO 4 Ultrium 1840 technology HP StorageWorks MSL6030 1 LTO 4...

Страница 26: ...art Array 70 HP StorageWorks 70 Modular Smart Array Enclosure 418800 B21 NOTE Please see the Modular Smart Array 70 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at http h18000 www1 hp com products quickspecs 12652_div 12652_div html Worldwide HP StorageWorks Modular Smart Array 500 HP StorageWorks Modular Smart Array 500 ...

Страница 27: ...SLES10 307754 B27 HP Serviceguard for Linux and Red Hat Global File System 1 year subscription T2798AA 001 HP Serviceguard for Linux and Red Hat Global File System 3 years subscription T2798AA 003 NOTE For additional information regarding HP Serviceguard for Linux please see the following QuickSpecs at http h18000 www1 hp com products quickspecs 11518_div 11518_div html Worldwide NOTE For configur...

Страница 28: ...JPN AF424A HP R3000 VA UPS 2U L5 30 JPN AF425A HP R5500 VA UPS INTL AF416A HP R5500 VA UPS NA JPN AF426A HP Monitored Power Distribution Unit PDU HP Monitored Power Distribution Unit Full Rack Version 17 3 kVA Monitored PDU Model S2324 AF503A 8 6 kVA Monitored PDU Model S1324 AF504A 16 6 kVA Monitored PDU Model S2140 AF505A 8 3 kVA Monitored PDU Model S1140 AF506A 22 kVA Monitored PDU Model S2316 ...

Страница 29: ... hp com products quickspecs 11041_div 11041_div html Worldwide USB Options HP USB 2 Button Optical Scroll Mouse Carbonite Silver DC172B USB 1 44 MB External Diskette Drive Carbonite DC141B HP USB 04 Standard Keyboard DT528A ABA HP 1GB USB 2 0 Floppy Drive Key 442085 B21 HP 256MB USB 2 0 Floppy Drive Key 442084 B21 Rack Conversion Kit HP ML350 G5 Tower to Rack Conversion Kit 412640 B21 ProLiant DL3...

Страница 30: ...such as height width depth weight and color http h18000 www1 hp com products quickspecs 12402_div 12402_div html Worldwide NOTE For additional information regarding Rack Cabinets please see the following URL http www hp com go rackandpower HP Rack 10000 Series Graphite Metallic HP S10614 14U Rack Cabinet Shock Pallet 292302 B22 NOTE xxxxxx B22 shock pallet used to ship racks with equipment install...

Страница 31: ...65A TFT7600 Rackmount Keyboard Monitor INTL AG066A 1U Rackmount Keyboard with USB US AG072A 1U Rackmount Keyboard with USB UK AG073A 1U Rackmount Keyboard with USB GR AG074A 1U Rackmount Keyboard with USB FR AG075A 1U Rackmount Keyboard with USB ITL AG076A 1U Rackmount Keyboard with USB SP AG077A 1U Rackmount Keyboard with USB DEN AG078A 1U Rackmount Keyboard with USB NOR AG079A 1U Rackmount Keybo...

Страница 32: ...l Adapter RJ45 DB9 DCE Female 1 Pack AF103A Serial Adapter RJ45 DB9 DCE Female 8 Pack AF110A NOTE Cat5e cables are required to connect Serial Adapters to Serial Console Servers Additional Serial Adapters and Cat5e cables can be found at the following URL http www hp com go kvm NOTE For additional information regarding KVM switches Serial Console servers rack mount monitors keyboards and all relate...

Страница 33: ...te onsite at HP s discretion 24x7 2hr response time incl HP holidays Electronic U6308E Onsite HW support 24x7 4hr response and Red Hat ES Linux SW Tech support offsite onsite at HP s discretion 24x7 2hr response time incl HP holidays Electronic U8330E NOTE For more information customer resellers can contact http www hp com services carepack QuickSpecs HP ProLiant ML350 Generation 5 Options DA 1247...

Страница 34: ... B21 4 GB FBD PC2 5300 2 x 2 GB Kit 397413 B21 4 GB FBD PC2 5300 2 x 2 GB LP Kit 461828 B21 8 GB FBD PC2 5300 2 x 4 GB Kit 397415 B21 Online spare memory configuration FBDIMMs can either be single rank or dual rank Certain FBDIMM configuration requirements are based on these classifications A dual rank FBDIMM is similar to having two separate FBDIMMs or ranks on the same module Although only a sin...

Страница 35: ...X X X X X X X QuickSpecs HP ProLiant ML350 Generation 5 Memory DA 12475 Worldwide QuickSpecs Version 20 11 27 2007 Page 35 ...

Страница 36: ...troller IDE ATAPI CD ROM Drive Up to 1 A B C D E Integrated SATA Controller HP DVD R RW 16X Half Height Up to 1 A B C D E Integrated SATA Controller DVD ROM Drive Option Kit Up to 1 A B C D E Integrated SATA Controller HP Half Height SATA DVD ROM Optical Drive Up to 1 A B C D E Integrated SATA Controller HP Half Height SATA DVD RW Optical Drive Up to 1 A B C D E Integrated SATA Controller QuickSpe...

Страница 37: ...gurations Hot Plug SFF SAS 2 5 Drives Quantity Supported Position Supported Controller 146GB 3G SAS 10K SP 146GB 3G SAS 10K DP 72GB 3G SAS 10K SP 72GB 3G SAS 10K DP 72GB 3G SAS 15K SP 72GB 3G SAS 15K DP 36GB 3G SAS 10K SP 36GB 3G SAS 15K SP 36GB 3G SAS 15K DP Up to 8 SFF 1 8 HP Smart Array E200i 64MB Controller HP Smart Array E200i 128 BBWC Controller HP Smart Array E500 256MB Controller HP Smart ...

Страница 38: ...each of the Tape Drives listed below please see the following http h18000 www1 hp com products quickspecs division 10233 html Worldwide NOTE For an up to date listing of the latest O S Support details for each of the Tape Autoloaders and Tape Libraries listed below please see the following http h18000 www1 hp com products quickspecs division 10809 html Worldwide NOTE For complete listing of tape d...

Страница 39: ...mart Array E500 Controller 435129 B21 NOTE The following SAS Smart Array controllers require ROM Flash version 2 04 or higher for SAS tape support HP Smart Array P400 256MB Controller 405132 B21 HP Smart Array P400 512MB Controller 411064 B21 HP StorageWorks SAS Tape Drives External LTO 2 Ultrium 448 SAS LTO 3 Ultrium 920 SAS 1U Rack Mount Kit External HP SC44Ge Host Bus Adapter NOTE Recommended 4...

Страница 40: ...ntroller firmware version and SAS cabling requirements 416096 B21 HP StorageWorks Fibre Tape Automation External MSL2024 MSL4048 MSL6000 External Please consult the EBS connectivity matrix at http www hp com go ebs for detailed connectivity information N A HP StorageWorks D2D Backup Systems D2D110 D2D120 External Embedded Network Controller N A QuickSpecs HP ProLiant ML350 Generation 5 Storage DA ...

Страница 41: ... 98 0 98 0 98 0 98 0 98 0 98 Leakage Current mA 0 44 0 52 0 91 0 96 1 00 1 04 Maximum Inrush Current A peak 30 30 30 30 30 30 Maximum Inrush Current duration miliseconds 3 3 3 3 3 3 NOTES ActiveAnswers Power Calculation Power calculator is LIVE on ActiveAnswers Web site This is an external link Follow this link http h30099 www3 hp com configurator powercalcs asp To drill down to calculators Click ...

Страница 42: ... Rating BTU HR 3350 BTU hr at 100 VAC 3530 BTU hr at 120 VAC 3990 BTU hr at 240 VAC Power Specifications To review typical system power ratings use the Power Calculator which is available via the online tool located at URL http h30099 www3 hp com configurator calc Power 20Calculator 20Catalog xls Click on the system of interest Example ML350 G5 Follow the instructions of the next screens Power Sup...

Страница 43: ...nment Noise emissions were measured in accordance with ISO 7779 ECMA 74 and declared in accordance with ISO 9296 ECMA 109 Idle L WAd 5 2 B L pAm 35 dBA Operating L WAd 5 3 B L pAm 35 dBA Smart Array E200i Controller Disk Drive and Enclosure Interface 3G SAS Serial Attached SCSI 1 5G SATA Serial Advanced Technology Attachment SAS Connectors 2 internal SFF8484 x4 wide port connectors Cache Memory Sp...

Страница 44: ...sponsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrat...

Отзывы: