Removal and replacement procedures 50
8.
If the cache module is connected to a capacitor pack, disconnect the capacitor pack cable from the
connector on the top of the cache module.
To replace the component, reverse the removal procedure.
CAUTION:
To prevent damage to the cache module during installation, be sure the cache
module is fully inserted before pressing down.
Flash-backed write cache capacitor pack
To remove the component:
1.
Back up all data.
2.
Close all applications.
3.
Power down the server (on page
27
).
CAUTION:
In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.
4.
Do one of the following:
o
Open or remove the tower bezel, as needed ("
Front bezel
" on page
29
).
o
Extend the server from the rack.
5.
Remove the access panel ("
Access panel
" on page
30
).
All manuals and user guides at all-guides.com
Содержание PROLIANT ML350 G6
Страница 12: ...Customer self repair 12 All manuals and user guides at all guides com ...
Страница 13: ...Customer self repair 13 All manuals and user guides at all guides com ...
Страница 14: ...Customer self repair 14 All manuals and user guides at all guides com ...
Страница 15: ...Customer self repair 15 All manuals and user guides at all guides com ...
Страница 19: ...Illustrated parts catalog 19 All manuals and user guides at all guides com ...
Страница 26: ...Illustrated parts catalog 26 All manuals and user guides at all guides com a l l g u i d e s c o m ...