Removal and Replacement Procedures
•
If there is not an online spare configured:
1. Power down the server, and then replace the failed drive.
2. Reboot the server.
3. Rebuild the array, choosing one of the following options:
a. Run the Integrated ATA RAID Configuration Utility by pressing the
F8
key, and
then run
Rebuild
.
or
b. Let the auto-rebuild take place when the operating system is up and running.
Refer to “Integrated ATA RAID Configuration Utility” in this chapter for information on the
utility menu options.
RAID 1+0 Configurations
NOTE:
RAID 1+0, RAID 0+1, and RAID 10 are used synonymously.
Four ATA hard drives are required to support a RAID 1+0 configuration.
In a RAID 1+0 situation, multiple drive failures can be handled as long as both elements of a
mirror have not failed.
To rebuild the array:
1. Power down the server, and then replace the failed drive.
2. Reboot the server.
3. Rebuild the array, choosing one of the following options:
a. Run the Integrated ATA RAID Configuration Utility by pressing the
F8
key, and
then run
Rebuild
.
or
b. Let the auto-rebuild take place when the operating system is up and running.
Refer to “Integrated ATA RAID Configuration Utility” in this chapter for information on the
utility menu options.
Integrated ATA RAID Configuration Utility
The setup screen of the Integrated ATA RAID Configuration Utility has three menu
windows:
•
•
•
Array Information
Physical Drive Information
Help Information
HP ProLiant ML310 Server Maintenance and Service Guide
2-21