System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions (HxWxD)
(with feet)
14.5 x 6.9 x 16.8 in (36.7x 17.5 x 42.6 cm)
Weight
Weight
Weight
Weight (approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
31.35 lb (14.22 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
25.75 lb (11.68 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Rated Line Voltage
90 –- 132 VAC,
180 – 264 VAC
Rated Input Current
6 A (at 110 VAC),
3 A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
365 W (at 100 VAC),
365 W (at 200 VAC)
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Maximum
1885 BTU/hr (at 100 VAC),
U/hr (at 200 VAC)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/calc
/Power%20Calculator%20Catalog.xls
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power 365 W (at 100 VAC),
365 W (at 200 VAC)
Maximum Peak Power
385 W (at 100 VAC),
385 W (at 200 VAC
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
10 to 90% relative humidity (Rh), 28°C
5 to 95% relative humidity (Rh), 38.7°C
Altitude
Altitude
Altitude
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
(Fully Loaded)
Idle
LLLL WAd
4.74 BELS
QuickSpecs
HP ProLiant ML115 Generation 5 (G5)
HP ProLiant ML115 Generation 5 (G5)
HP ProLiant ML115 Generation 5 (G5)
HP ProLiant ML115 Generation 5 (G5)
Technical Specifications
DA - 13013 North America — Version 8 — September 15, 2008