Removal and replacement procedures 48
To install the heat sink:
CAUTION:
To prevent overheating or a possible system crash, use only a heat sink specified for your
ProLiant server.
1.
If you are using a new heat sink, remove the cover protecting the preapplied thermal compound.
Be careful not to touch or scratch the thermal compound.
IMPORTANT:
Make sure the heat sink cable is not caught underneath the heat sink during
installation.
2.
Install the heat sink.
a.
Insert the spring-loaded screws into the system board holes (
1
).
b.
Use a T-15 Torx screwdriver to tighten the spring-loaded screws (
2
).
c.
Connect the heat sink cable to its system board connector (
3
).
3.
Perform the post-installation procedure.