System Unit
Dimensions (H x W x
D) (with feet)
9.15 x 9.06 x 9.65 in (23.24x 23 x 24.5 cm)
Weight (approximate) Maximum
(all hard drives, power
supply and processor
installed)
21.60 lb (9.8 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
15.13 lb (6.8 kg)
Input Requirements
(per power supply)
Rated Line Voltage
100 -- 127 VAC,
200 - 240 VAC
Rated Input Current
3.5 A (at 110 VAC),
2 A (at 200 VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
For 150W Power Supply
192 W (at 100 VAC),
185 W (at 200 VAC)
For 200W Power Supply
243 W (at 100 VAC),
237 W (at 200 VAC)
BTU Rating
Maximum
For 150 W Power Supply
682 BTU/hr (at 100 VAC),
665 BTU/hr (at 200 VAC)
For 200 W Power Supply
838.86 BTU/hr (at 100 VAC),
825.22 BTU/hr (at 200 VAC)
Power Specifications
To review typical system power ratings use the Power Advisor
which is available via the online tool located at URL:
http://www.hp.com/go/hppoweradvisor
Power Supply Output
(per power supply)
Rated Steady-State
Power
For 150 W Power Supply
150 W (at 100 VAC),
150 W (at 200 VAC)
For 200 W Power Supply
200 W (at 100 VAC),
200 W (at 200 VAC)
Maximum Peak Power
For 150 W Power Supply
150 W (at 100 VAC),
150 W (at 200 VAC)
For 200 W Power Supply
200 W (at 100 VAC),
200 W (at 200 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea
level with an altitude derating of
1.0°C per every 305 m (1.8°F per
every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no
direct sustained sunlight. Maximum
rate of change is 10°C/hr (18°F/hr).
The upper limit may be limited by the
type and number of options installed.
System performance may be
QuickSpecs
HPE ProLiant MicroServer Generation 8 (Gen8)
Technical Specifications
DA - 14565 Worldwide QuickSpecs — Version 24 — 12.17.2015
Page 30