System Unit
Dimensions
(H x W x D)
(with bezel)
12.04 x 17.32 x 27.4 in (30.58 x 44 x 69.6cm)
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
160lb (72 kg)
Minimum
(one hard drive, 2 power
supply, and 4 processor
modules installed)
147 lb (67 kg)
Input Requirements
(per 3 power supplies
non redundant)
Rated Line Voltage
90 - 132 VAC
180 - 264 VAC
Rated Input Current
24A @ 100 VAC
14A @ 200 VAC
Rated Input Frequency
47 to 63 Hz
Rated Input Power
2400W @ 100-120 VAC
2800W @ 200-240 VAC
BTU Rating
Maximum
8189 BTU/hr @ 100-120 VAC
9554 BTU/hr @ 200-240 VAC
Power Specifications
NOTE:
To review typical system power ratings use the HP Power
Advisor which is available online located at url:
www.hp.com/go/proliant-
energy-efficient
or
www.hp.com/go/hppoweradvisor
Click on the system of interest. Example: DL785 G5
Follow the instructions of the next screens
Power Supply Output
(per power supply)
Rated Steady-State
Power
800 W (at 100 VAC),
1200 W (at 200 VAC)
Maximum Peak Power
800 W (at 100 VAC),
1200 W (at 200 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed. System performance may be
reduced if operating with a fan fault or above
30°C (86°F).
Non-operating
-30° to 60° (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.
Non-operating
5% to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non condensing.
Altitude
Operating
3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min)
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
QuickSpecs
HP ProLiant DL785 Generation 5
Technical Specifications
DA - 13046 Worldwide QuickSpecs — Version 25 — 8/16/2010
Page 40