Removal and replacement procedures 31
WARNING:
This server is very heavy. To reduce the risk of personal injury or damage to the
equipment:
•
Observe local occupational health and safety requirements and guidelines for manual
material handling.
•
Get help to lift and stabilize the product during installation or removal, especially when the
product is not fastened to the rails. Hewlett Packard Enterprise recommends that a
minimum of two people are required for all rack server installations. A third person may be
required to help align the server if the server is installed higher than chest level.
•
Use caution when installing the server in or removing the server from the rack; it is unstable
when not fastened to the rails.
To remove the server from a Hewlett Packard Enterprise, Compaq-branded, Telco, or a third-party
enclosure:
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Disconnect all peripheral cables from the server.
4.
Remove the server from the rack.
For instructions on how to extend or remove the server from the rack, see the documentation that
ships with the rack rail system.
5.
Place the server on a sturdy, level surface.
Remove the air baffle
CAUTION:
For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components,
minimize the amount of time the access panel is open.
To remove the component:
1.
Power down the server (on page
2.
If you are performing a non-hot-plug procedure, remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
o
Remove the server from the rack (on page
4.
Remove the access panel ("
5.
Remove the air baffle.
Содержание ProLiant DL60 Gen9
Страница 5: ...Contents 5 Documentation feedback 111 Index 112 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 23: ...Illustrated parts catalog 23 ...
Страница 33: ...Removal and replacement procedures 33 o Secondary PCI riser cage o PCI blank ...
Страница 95: ...Component identification 95 Fan locations ...
Страница 100: ...Cabling 100 FBWC module slot 3 cabling M 2 SSD cabling Slot 2 cable routing 2 ports supported when slot 1 is unoccupied ...
Страница 110: ...Acronyms and abbreviations 110 UID unit identification USB universal serial bus ...