Removal and replacement procedures 37
4.
Remove the hot-plug drive.
To replace the component, reverse the removal procedure.
Access panel
To remove the component:
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
Do not operate the server for long periods with the access panel open or
removed. Operating the server in this manner results in improper airflow and improper cooling
that can lead to thermal damage.
1.
Power down the server (on page
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
o
Extend the server from the rack (on page
o
Remove the server from the rack (on page
4.
Open the access panel latch, slide the access panel to the rear of the chassis, and then remove the
access panel.