Removal and replacement procedures 55
2.
Power down the failed server ("
Power down the server
" on page
26
). If any data is trapped in the
cache module, an amber LED on the module blinks every 15 seconds.
CAUTION:
Do not detach the cable that connects the battery pack to the cache module.
Detaching the cable causes any unsaved data in the cache module to be lost.
3.
Transfer the hard drives from the failed server to the recovery server station.
4.
Remove the BBWC [cache module ("
Removing the cache module
" on page
51
) and battery pack
("
BBWC battery pack
" on page
53
)] from the failed server.
5.
Perform one of the following:
o
Install the BBWC into an empty BBWC DIMM socket on the system board of the recovery server.
o
Install the BBWC into an empty BBWC DIMM socket on any Smart Array Controller in the
recovery server.
6.
Power up the recovery server. A 1759 POST message is displayed, stating that valid data was
flushed from the cache. This data is now stored on the drives in the recovery server. You can now
transfer the drives (and controller, if one was used) to another server.
System cage
Installing or accessing some options or components in the server might require removing the system cage.
See the instructions for each individual option to determine if removing the system cage is necessary.
To remove the system cage:
1.
Power down the server (on page
26
).
2.
Remove the server from the rack (on page
28
).
3.
Remove the access panel ("
Removing the access panel
" on page
28
).
4.
Remove all hot-plug power supplies ("
Power supply
" on page
45
).
5.
Remove fans 3 through 6 installed in front of the power supply cages ("
Fan locations
" on page
81
).
6.
Remove all expansion boards ("
Expansion boards
" on page
48
).
7.
Remove all expansion slot covers ("
Expansion slot covers
" on page
47
).
8.
Remove the pass-through board ("
Pass-through board
" on page
50
).
9.
Loosen the thumbscrews, and lift the system cage from the server.
NOTE:
The T-15 Torx screwdriver can be used to loosen the thumbscrews. The T-15 Torx
screwdriver is shipped with the server and can be located on the rear panel ("
Rear panel
components
" on page
73
).
Содержание ProLiant DL585 Generation 2
Страница 5: ...Contents 5 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...Customer self repair 16 ...
Страница 24: ...Illustrated parts catalog 24 ...
Страница 95: ...Index 95 video connector cabling 33 83 ...