![HP ProLiant DL580 Generation 3 Скачать руководство пользователя страница 104](http://html.mh-extra.com/html/hp/proliant-dl580-generation-3/proliant-dl580-generation-3_user-manual_164788104.webp)
104
HP ProLiant DL580 Generation 3 Server User Guide
Advanced Memory
Protection Mode
Hot-
Replace
Supported
Hot-Add
Supported
Online Spare Memory
Hot-Plug Mirrored Memory
X
Hot-Plug RAID Memory
X
When the server is configured for hot-plug mirrored memory or hot-plug RAID
memory, you can perform a hot-replacement procedure in the following manner
without powering down the server or experiencing server downtime:
1.
Remove a memory board.
2.
Replace failed or degraded DIMMs.
3.
Reinstall the memory board in the slot from which it was removed.
The replacement procedures in this section apply to both hot-plug and non-hot-
plug memory procedures, except as noted.
IMPORTANT: Be sure to power down the server when performing
board removal procedures in a server that is not configured for
Advanced ECC, hot-plug mirrored memory, or hot-plug RAID memory.
Observe the following warnings when performing a hot-plug replacement
procedure.
WARNING: Always comply with all electrostatic and thermal
guidelines to prevent bodily injury and ensure a properly
functioning system when performing hot-plug operations.
WARNING: To prevent personal injury from hazardous
energy:
•
Remove watches, rings, or other metal objects.
•
Use tools with insulated handles.
•
Do not place tools or metal parts on top of batteries.
Содержание ProLiant DL580 Generation 3
Страница 1: ...HP ProLiant DL580 Generation 3 Server User Guide April 2005 Second Edition Part Number 379044 002 ...
Страница 8: ......
Страница 36: ......
Страница 46: ...46 HP ProLiant DL580 Generation 3 Server User Guide ...
Страница 76: ...76 HP ProLiant DL580 Generation 3 Server User Guide 4 Power up the server Powering up the server on page 37 ...
Страница 109: ...Memory options 109 3 Use the ejector lever to pull the memory board out of the server 4 Open the memory board ...
Страница 114: ......
Страница 121: ...Server cabling 121 9 Remove the power switch cable assembly To replace the component reverse the removal procedure ...
Страница 122: ......
Страница 152: ...152 HP ProLiant DL580 Generation 3 Server User Guide ...
Страница 154: ...154 HP ProLiant DL580 Generation 3 Server User Guide ...
Страница 157: ...Troubleshooting 157 ...
Страница 159: ...Troubleshooting 159 ...
Страница 161: ...Troubleshooting 161 ...
Страница 162: ...162 HP ProLiant DL580 Generation 3 Server User Guide ...
Страница 165: ...Troubleshooting 165 ...
Страница 170: ......
Страница 180: ......