Figure 8 Disk management, partitioning (ML110 G1 and
DL100)
Under normal circumstances, the ML110 G1 and DL100 storage server
boots up from the primary OS logical drive. If the system experiences a
drive failure, the Adaptec 2410SA sounds an audible alert to inform the
user of a drive failure.
•
If a single drive failure occurs, it is transparent to the OS.
•
If a second drive fails, the data volume is lost and must be restored
from backup.
When the primary OS has a failure such as system
fi
les becoming
corrupted, registry corrupted, and the system hangs during boot, the
system should be run from the secondary OS. To run the system from the
secondary OS:
1.
Power down the unit.
2.
Connect a monitor, keyboard, and mouse directly to the rear of the
unit.
3.
Power on the unit.
4.
During boot up, select to use the secondary partition.
The user should backup their user data and then use the Quick Restore DVD
to restore the system to the factory default state as soon as conveniently
possible.
HP ProLiant Storage Server user guide
45