Removal and replacement procedures 34
8.
Remove the PCIe riser board.
To replace the component, reverse the removal procedure.
Drive blank
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
Remove the drive blank.
To replace the component, slide the component into the bay until it clicks.
Hot-plug drive
CAUTION:
For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
1.
Determine the status of the drive from the hot-plug drive LED definitions (on page
77
).
2.
Back up all server data on the drive.