Component identification 91
Systems Insight Display
LED and color
Health LED
System power
LED
Status
Power supply (amber)
Red
Amber
•
Only one power supply is installed and
that power supply is in standby.
•
Power supply fault
•
System board fault
Power supply (amber)
Amber
Green
•
Redundant power supply is installed and
only one power supply is functional.
•
AC power cord is not plugged into
redundant power supply.
•
Redundant power supply fault
•
Power supply mismatch at POST or
power supply mismatch through hot-plug
addition.
Power cap (off)
—
Amber
Standby
Power cap (green)
—
Flashing green
Waiting for power
Power cap (flashing
amber)
—
Amber
Power cap has been exceeded
Power cap (green)
—
Green
Power is available
IMPORTANT:
If more than one DIMM slot LED is illuminated, further troubleshooting is required.
Test each bank of DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing
each DIMM in a bank with a known working DIMM.
Rear panel components
Item Description
1
PCI slot 5
2
PCI slot 6
3
PCI slot 4
4
PCI slot 2
5
PCI slot 3
6
PCI slot 1
7
Power supply bay 2
8
Power supply bay 1 (populated)
9
USB connectors (2)
Содержание ProLiant DL380 G7
Страница 5: ...Contents 5 Index 110 ...
Страница 13: ...Customer self repair 13 ...
Страница 14: ...Customer self repair 14 ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...Customer self repair 16 ...
Страница 20: ...Illustrated parts catalog 20 System components ...
Страница 63: ...Removal and replacement procedures 63 6 Open the heatsink retaining bracket 7 Remove the heatsink ...
Страница 82: ...Cabling 82 Cabling SAS hard drive cabling Optical drive cabling ...
Страница 83: ...Cabling 83 BBWC battery cabling FBWC capacitor pack cabling ...