Removal and replacement procedures 48
7.
Remove the fans ("
" on page
8.
Remove the fan cage.
To replace the component, reverse the removal steps. When re-installing the fans, press down on the top of
each fan to be sure it is seated properly.
Expansion slot covers
CAUTION:
To prevent damage to the server or expansion boards, power down the server and
remove all AC power cords before removing or installing the PCI riser cage.
CAUTION:
For proper cooling do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
1.
Power down the server (on page
2.
Extend the server from the rack (on page
3.
Remove the access panel ("
" on page
4.
Remove the PCI riser cage ("
" on page
5.
Remove the expansion slot cover: