QuickSpecs
HPE ProLiant DL360 Generation9 (Gen9)
Technical Specifications
Page 59
1.0°C per every 175 m (1.8°F per every 574 ft)
above 900 m (2953 ft) to a maximum of 3050 m
(10,000 ft). The approved hardware
configurations for this system are listed at the
URL:
http://www.hpe.com/servers/ashrae
For approved hardware configurations, the
supported system inlet range is extended to be:
40° to 45°C (104° to 113°F) at sea level with an
altitude derating of 1.0°C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft). The approved
hardware configurations for this system are listed
at the URL:
http://www.hpe.com/servers/ashrae
System performance may be reduced if operating
in the extended ambient operating range or with
a fan fault.
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Operating
Minimum to be the higher (more moisture) of -
12°C (10.4°F) dew point or 8% relative humidity.
Maximum to be the lower (less moisture) of 24°C
(75.2°F) dew point or 90% relative humidity.
(non-condensing)
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-condensing.
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA 74)
and declared in accordance with ISO 9296 (ECMA 109).
Idle
LWAd
(1P non-redundant) 4.6 A Average Bystander
(2P redundant) 5.5 A Average Bystander
LpAm
(1P non-redundant) 29 dBA
(2P redundant) 37
dBA
Operating
LWAd
(1P non-redundant) 4.6 A Average Bystander
(2P redundant) 6.2 C Average Bystander
LpAm
(1P non-redundant) 30 dBA
(2P redundant) 46 dBA