Specification
Value
BTUs per hour
3,067 at 100 VAC
2,958 at 200 VAC
2,949 at 240 VAC for China only
Power supply output
Rated steady-state power
800 W at 100 VAC to 127 VAC input
800 W at 100 VAC to 240 VAC input
800 W at 240 VDC input for China only
Maximum peak power
800 W at 100 VAC to 127 VAC input
800 W at 100 VAC to 240 VAC input
800 W at 240 VDC input for China only
HPE 800W Flex Slot Titanium Hot Plug Low Halogen Power Supply
Specification
Value
Input requirements
Rated input voltage
200 VAC to 240 VAC
240 VDC for China only
Rated input frequency
50 Hz to 60 Hz
Not applicable to 240 VDC
Rated input current
4.35 A at 200 VAC 3.62 A at 240 VAC
3.62 A at 240 VDC for China only
Maximum rated input power
851 W at 200 VAC
848 W at 240 VAC
848 W at 240 VDC for China only
BTUs per hour
2,905 at 200 VAC
2,969 at 240 VAC
2,969 at 240 VDC for China only
Power supply output
Rated steady-state power
800 W at 200 VAC to 240 VAC input
800 W at 240 VDC input for China only
Maximum peak power
800 W at 200 VAC to 240 VAC input
800 W at 240 VDC input for China only
HPE 800W Flex Slot Titanium Hot Plug Low Halogen Power Supply
135
Содержание ProLiant DL360 Gen10
Страница 75: ...9 Install the full height PCIe x16 riser cage latch 10 Install the riser cage Hardware options installation 75 ...
Страница 79: ... Full length 9 Install the expansion board Hardware options installation 79 ...
Страница 96: ... 4 LFF 9 Guide the SID cable through the front of the server 96 Hardware options installation ...