Description
Status
Processor LEDs
Off = Normal
Amber = Failed processor
DIMM LEDs
Off = Normal
Amber = Failed DIMM or configuration issue
Fan LEDs
Off = Normal
Amber = Failed fan or missing fan
NIC LEDs
Off = No link to network
Solid green = Network link
Flashing green = Network link with activity
If power is off, the front panel LED is not active. For
status, see
Power supply LEDs
Off = Normal
Solid amber = Power subsystem degraded, power
supply failure, or input power lost.
PCI riser LED
Off = Normal
Amber = Incorrectly installed PCI riser cage
Over temp LED
Off = Normal
Amber = High system temperature detected
Amp Status LED
Off = AMP modes disabled
Solid green = AMP mode enabled
Solid amber = Failover
Flashing amber = Invalid configuration
Power cap LED
Off = System is in standby, or no cap is set.
Solid green = Power cap applied
When the health LED on the front panel illuminates either amber or red, the server is experiencing a health
event. For more information on the combination of these LEDs, see
Systems Insight Display combined
on page 85).
Systems Insight Display combined LED descriptions
The combined illumination of the following LEDs indicates a system condition:
• Systems Insight Display LEDs
• System power LED
• Health LED
Systems Insight Display combined LED descriptions
85
Содержание ProLiant DL360 Gen10
Страница 27: ...Customer self repair 27 ...
Страница 28: ...28 Customer self repair ...
Страница 29: ...Customer self repair 29 ...
Страница 30: ...30 Customer self repair ...
Страница 35: ...Removing and replacing the bezel Removing and replacing the bezel 35 ...
Страница 66: ...6 Remove the component SFF LFF 66 Removal and replacement procedures ...