Rated Input Current
460 Watt
7.1 A (at 120 VAC)
3.5 A (at 240 VAC)
750 Watt
7.4 A (at 120 VAC)
3.6 A (at 240 VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
460 & 750 watt - 852 W
BTU Rating
Maximum
460 Watt
1773 BTU/hr (at 12
VAC)
1715 BTU/hr (at 24
VAC)
750 Watts
2892 BTU/hr (at 12
VAC)
2797 BTU/hr (at 24
VAC
Power Specifications
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL:
www.hp.com/go/proliant-
energy-efficient
•
Click on the system of interest. Example: DL288 G6
•
Follow the instructions of the next screens.
Power Supply Output
(per power supply)
Rated Steady-State Power 460 W (at 100 VAC)
750 W (at 100 VAC)
460 W (at 200 VAC)
750 W (at 200 VAC)
Maximum Peak Power
460 W (at 100 VAC)
750 W (at 100 VAC)
460 W (at 200 VAC)
750 W (at 200 VAC)
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate
of change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C