Removing and replacing a transceiver
Removing and replacing a transceiver
Prerequisites
Prerequisites
Before replacing a transceiver, review the following:
Transceiver warnings and cautions
Transceiver documentation for specific operational and cabling requirements
Procedure
Procedure
1. Disconnect the network cable from the transceiver.
2. Slide the transceiver out of the network adapter port.
See the transceiver documentation for model-specific release mechanism for removing the transceiver.
To replace the component, reverse the removal procedure.
Removing and replacing a transceiver
100
Содержание ProLiant DL20 Gen10 Plus
Страница 41: ...Customer self repair 41 ...
Страница 42: ...Customer self repair 42 ...
Страница 43: ...Customer self repair 43 ...
Страница 44: ...Customer self repair 44 ...
Страница 61: ...quick release chassis ears c Repeat step a and b to remove the left ear Remove the chassis ear 61 ...
Страница 64: ...Remove the front panel cover 64 ...
Страница 81: ...To replace the component reverse the removal procedure Removing and replacing a fan 81 ...
Страница 85: ...To replace the component reverse the removal procedure Removing and replacing a LFF non hot plug drive 85 ...
Страница 93: ...To replace the component reverse the removal procedure Removing and replacing the 2 LFF drive backplane 93 ...
Страница 97: ...To replace the component reverse the removal procedure Removing and replacing the 4 SFF drive backplane 97 ...
Страница 122: ...Removing and replacing a boot device drive 122 ...
Страница 133: ...To replace the component reverse the removal procedure Removing and replacing a Flexible Slot power supply 133 ...
Страница 140: ...Heatsink replacement Removing the heatsink Installing the heatsink Heatsink replacement 140 ...
Страница 144: ...4 Install the processor air baffle 5 Install the M 2 air baffle Installing the heatsink 144 ...
Страница 146: ...Processor replacement Removing the processor Installing the processor Processor replacement 146 ...
Страница 151: ...14 Hold the processor by the edges and then lift it out of the socket Removing the processor 151 ...
Страница 155: ...7 Install the processor air baffle 8 Install the M 2 air baffle Installing the processor 155 ...
Страница 161: ...19 Hold the processor by the edges and then lift it out of the socket Removing the system board 161 ...
Страница 163: ...Removing the system board 163 ...
Страница 169: ...Troubleshooting NMI functionality Troubleshooting resources Troubleshooting 169 ...
Страница 189: ...DIMM slot location The arrow points to the front of the server DIMM slot location 189 ...
Страница 199: ...Fan numbering Fan numbering 199 ...
Страница 204: ...Cabling This chapter includes cabling guidelines and diagrams for internal component cabling Cabling 204 ...
Страница 219: ...Energy pack cabling Energy pack cabling 219 ...
Страница 224: ...M 2 SATA SSD add in card cabling 224 ...
Страница 226: ...Fan cabling Color Description Orange Fan 1 cable Blue Fan 2 cable Gold Fan 3 cable Fan cabling 226 ...
Страница 227: ...Chassis intrusion detection switch cabling Chassis intrusion detection switch cabling 227 ...
Страница 228: ...Serial port cabling Serial port cabling 228 ...
Страница 230: ...Power supply cabling 230 ...