background image

HP StorageWorks 1/8 G2 Tape Autoloader

HP StorageWorks 1/8 G2 Tape Autoloader

HP StorageWorks 1/8 G2 Tape Autoloader

HP StorageWorks 1/8 G2 Tape Autoloader

 

HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader

AK377A

HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader

AH558A

HP StorageWorks 1/8 G2 LTO-2 Ultrium 448 Tape Autoloader

AH164A

HP StorageWorks 1/8 G2 Tape Autoloader Rack Kit

NOTE:

NOTE:

NOTE:

NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack;
includes rails and rackmount instructions.

AH166A

NOTE:

NOTE:

NOTE:

NOTE: Please see the QuickSpecs for Technical Specifications:

http://www.hp.com/go/automation

 and for additional information needed to create a

complete solution; reference current compatibility information at:

http://www.hp.com/go/ebs

.

 

Tape Libraries

Tape Libraries

Tape Libraries

Tape Libraries

 

HP StorageWorks MSL2024 Tape Library

HP StorageWorks MSL2024 Tape Library

HP StorageWorks MSL2024 Tape Library

HP StorageWorks MSL2024 Tape Library

 

HP StorageWorks MSL2024 1 LTO-4 Ultrium 1840 SCSI Drive Library

AJ033A

HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library

AK378A

HP StorageWorks MSL2024 1 LTO-3 Ultrium 960 SCSI Drive Library

AG115A

HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library

AH559A

HP StorageWorks MSL2024 1 LTO-2 Ultrium 448 SCSI Drive Library

AG116A

HP StorageWorks MSL4048 Tape Library

HP StorageWorks MSL4048 Tape Library

HP StorageWorks MSL4048 Tape Library

HP StorageWorks MSL4048 Tape Library

 

HP StorageWorks MSL4048 1 LTO-4 Ultrium 1840 SCSI Drive Library

AJ035A

HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Drive Library

AK380A

HP StorageWorks MSL4048 1 Ultrium 960 SCSI Drive Library

AG322A

HP StorageWorks MSL4048 1 Ultrium 920 SAS Drive Library

AH560A

NOTE:

NOTE:

NOTE:

NOTE: Please reference the QuickSpecs for Technical Specifications:

http://www.hp.com/go/automation

 and additional information needed to create a

complete solution; reference current compatibility information at:

http://www.hp.com/go/ebs

.

 

HP Disk Backup

HP Disk Backup

HP Disk Backup

HP Disk Backup

RDX Removable Disk Backup

RDX Removable Disk Backup

RDX Removable Disk Backup

RDX Removable Disk Backup

 

HP StorageWorks RDX160 External Removable Disk Backup System

NOTE: 

NOTE: 

NOTE: 

NOTE: 160GB of Disk Storage.

AJ766A

HP StorageWorks RDX320 External Removable Disk Backup System

NOTE: 

NOTE: 

NOTE: 

NOTE: 320GB of Disk Storage.

AJ768A

HP StorageWorks RDX500 External Removable Disk Backup System

NOTE:

NOTE:

NOTE:

NOTE: 500GB of Disk Storage.

AJ935A

NOTE: 

NOTE: 

NOTE: 

NOTE: Please see the QuickSpecs for Technical Specifications and additional
information:

http://h18000.www1.hp.com/products/quickspecs/13036_na/13036_na.html

 

D2D Backup

D2D Backup

D2D Backup

D2D Backup

 

HP StorageWorks D2D2504i Backup System

EJ002A

HP StorageWorks D2D120 Backup System with Data Protector Express Software Kit

NOTE:

NOTE:

NOTE:

NOTE: 2TB of Disk Storage.

EH924A

HP StorageWorks D2D130 Backup System with LTO-3 Ultrium 920 SAS Tape Drive

NOTE: 

NOTE: 

NOTE: 

NOTE: 3TB of Disk Storage.

EH952A

QuickSpecs

HP ProLiant DL185 Generation 5 (G5)

HP ProLiant DL185 Generation 5 (G5)

HP ProLiant DL185 Generation 5 (G5)

HP ProLiant DL185 Generation 5 (G5)

Additional Options

DA - 12864   North America — Version 28 — February 19, 2010

Page 24

Содержание ProLiant DL185

Страница 1: ...e Port green What s New What s New What s New What s New Support for SATA Hot Plug 3 5 Midline MDL Hard Drives Support for Smart Array Controller with BBWC At A Glance At A Glance At A Glance At A Glance The new HP ProLiant DL185 G5 is a 2U dual processor server designed for quality performance and flexible deployments to meet the needs of the emerging markets SMB market and Corporate scale out Pr...

Страница 2: ...rvers USB Ports USB Ports USB Ports USB Ports Five USB ports 2 up front 2 rear 1 internal optional Optical Drive Optical Drive Optical Drive Optical Drive Support for one optional Multi bay DVD NOTE NOTE NOTE NOTE For 12 hard drive models optical drive support is available via rear DVD cage kit P N 513168 B21 DVD Drive not included Optional Floppy USB only USB key Power Supply Power Supply Power S...

Страница 3: ...also designed for easy replacement but may involve added complexity Customers may choose to have HP replace Optional CSR parts at no charge Additional information regarding worldwide limited warranty and technical support is available at http h18004 www1 hp com products servers platforms warranty index html QuickSpecs HP ProLiant DL185 Generation 5 G5 HP ProLiant DL185 Generation 5 G5 HP ProLiant ...

Страница 4: ...processor Quad Core Model 2346HE 1 8 GHz 55W ACP AMD Opteron processor Quad Core Model 2344HE 1 7 GHz 55W ACP NOTE NOTE NOTE NOTE Processor wattage references reflect Average CPU Power ACP For more information on ACP visit http www amd com powernow Upgradeability Upgradeability Upgradeability Upgradeability Upgradeable to two processors Chipset Chipset Chipset Chipset ServerWorks HT2100 and HT1000...

Страница 5: ...r Bus Number Bus Number Bus Number Form Factor Form Factor Form Factor Form Factor Notes Notes Notes Notes 1 PCI Express x8 x8 4 Full Length Full Height 2 PCI Express x8 x8 3 Full Length Full Height 3 PCI Express x4 x8 5 Low Profile 1 PCI X 64 bit N A Dynamic Low Profile Device Number 1 2 PCI X 1333 N A Dynamic Low Profile Device Number 2 Optional With PCI X riser installed replacing Full Length F...

Страница 6: ...ormation regarding USB support http h18004 www1 hp com products servers platforms usb support html Graphics Graphics Graphics Graphics 32 MB shared supporting 1600x1200x16M resolution Form Factor Form Factor Form Factor Form Factor Rack 2U 3 5 in 8 89 cm Embedded Manageability Embedded Manageability Embedded Manageability Embedded Manageability Lights Out 100i HP Lights Out 100i Remote Management ...

Страница 7: ... Insight Control server deployment is a deployment solution for HP ProLiant and Integrity servers hosted on a Windows CMS It automates the process of deploying and provisioning server software enabling companies to quickly and easily adapt to changing business demands Insight Control server deployment includes software optimizations for HP servers including the HP scripting toolkits configuration ...

Страница 8: ...switching Ships Standard 1200 Watts High Efficiency 12V Hot Plug AC Power Supply Autoswitching 750 Watts Power Supply Redundant Hot Plug Autoswitching Optional 1200 Watts High Efficiency Power Supply Redundant Hot Plug Autoswitching CSCI 2007 2008 Optional NOTE NOTE NOTE NOTE Climate Savers Computing Initiative 2007 2008 Compliant NOTE NOTE NOTE NOTE Redundant Power Supply configuration for 1200W ...

Страница 9: ...pport for all 2 post Telco racks and threaded hole racks requires an additional option kit from Rack Solutions The Rack Solutions brackets can be purchased at www hp com go rackandpower HP Factory Express HP Factory Express HP Factory Express HP Factory Express Capability Capability Capability Capability HP Factory Express offers configuration customization integration and deployment services for ...

Страница 10: ...maximize system uptime Recommended Service Recommended Service Recommended Service Recommended Service Simplify ProLiant solution implementation maintenance and management Support Service Support Service Support Service Support Service 3 Year 24x7 4 hr Response service support coverage Deployment Service Deployment Service Deployment Service Deployment Service Hardware Installation only Enhanced S...

Страница 11: ... Hard Drive Hard Drive Hard Drive Hard Drive None ship standard Internal Storage Internal Storage Internal Storage Internal Storage 8TB maximum Optical Drive Optical Drive Optical Drive Optical Drive Optional Power Supply Power Supply Power Supply Power Supply 750Watts Hot plug Ships standard Fans Fans Fans Fans 4 system fans ship standard Non hot plug Non redundant Form Factor Form Factor Form Fa...

Страница 12: ...rk Controller Network Controller Network Controller Network Controller Integrated NC326i PCIe Dual Port Gigabit Server Adapter Storage Controller Storage Controller Storage Controller Storage Controller Smart Array E200 128 BBWC Controller Hard Drive Hard Drive Hard Drive Hard Drive Not included up to 8 3 5 hot plug hard drives supported Internal Storage Internal Storage Internal Storage Internal ...

Страница 13: ...Storage Controller Storage Controller Smart Array P400 256 Controller Hard Drive Hard Drive Hard Drive Hard Drive Not included up to 12 3 5 hard drives supported Internal Storage Internal Storage Internal Storage Internal Storage 14TB Maximum Optical Drive Optical Drive Optical Drive Optical Drive Rear DVD RW Power Supply Power Supply Power Supply Power Supply 750W 12V Hot Plug Redundant Power Sup...

Страница 14: ...rd Four 4 Non Hot Plug Fans Rack Mount 2U 3 5 in 8 89 cm Step 2 Choose Required Options only one of the following from each list unless otherwise Step 2 Choose Required Options only one of the following from each list unless otherwise Step 2 Choose Required Options only one of the following from each list unless otherwise Step 2 Choose Required Options only one of the following from each list unle...

Страница 15: ...side of the factory For all solutions please refer to the server QuickSpecs and User s Manual for detailed installation instructions 417836 B21 HP P410 ZM FIO Smart Array Controller 462860 B21 HP P410 256 FIO SA Cntrlr w Battery 491195 B21 HP P212 256 FIO SA Cntrlr w Battery 491191 B21 HP Smart Array P800 Controller 381513 B21 Step 3 Choose Additional Factory Integratable Options Step 3 Choose Add...

Страница 16: ...ions for Factory Integration NOTE NOTE NOTE NOTE For additional options please refer to the Core Options and Additional Options sections below QuickSpecs HP ProLiant DL185 Generation 5 G5 HP ProLiant DL185 Generation 5 G5 HP ProLiant DL185 Generation 5 G5 HP ProLiant DL185 Generation 5 G5 Configuration Information Factory Integrated Models DA 12864 North America Version 28 February 19 2010 Page 16...

Страница 17: ...00 2 x 512 MB Single Rank Kit 408850 B21 2 GB REG PC2 6400 2 x 1 GB Kit 497763 B21 2 GB REG PC2 5300 2 x 1 GB Low Power Single Rank Kit 483399 B21 2 GB REG PC2 5300 2 x 1 GB Single Rank Kit 408851 B21 4 GB REG PC2 6400 2 x 2 GB Kit 497765 B21 4 GB REG PC2 5300 2 x 2 GB Low Power Single Rank Kit 483401 B21 4 GB REG PC2 5300 2 x 2 GB Dual Rank Kit 408853 B21 8 GB REG PC2 6400 2 x 4 GB Low Power Kit ...

Страница 18: ...State Drives SATA Hot Plug 3 5 Midline MDL Solid State Drives SATA Hot Plug 3 5 Midline MDL Solid State Drives SATA Hot Plug 3 5 Midline MDL Solid State Drives HP 60GB 3G SATA 3 5in MDL 1y Wty SSD 570761 B21 HP 120GB 3G SATA 3 5in MDL 1y Wty SSD 570763 B21 NOTE NOTE NOTE NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspe...

Страница 19: ... Ethernet Adapters 10 Gigabit Ethernet Adapters 10 Gigabit Ethernet Adapters 10 Gigabit Ethernet Adapters HP NC522SFP Dual Port 10GbE Server Adapter NOTE NOTE NOTE NOTE A minimum of two Gigabytes 2 GB of server memory is required per each NC522SFP adapter NOTE NOTE NOTE NOTE Direct Attach Cable DAC for copper environments or fiber transceivers and cables for fiber optic environments must be purcha...

Страница 20: ...SO image and latest updates may be downloaded at no cost from http www hp com go ic linux click on Download button TC208A NOTE NOTE NOTE NOTE Licenses ship without media The Media Kit for Insight Control for Linux can be ordered separately or can be downloaded at http www hp com go ic linux click on Download button NOTE NOTE NOTE NOTE Electronic licenses can be used to purchase multiple licenses w...

Страница 21: ... Array P410 Controller HP Smart Array P410 Controller HP Smart Array P410 Controller HP Smart Array P410 Controller HP P410 256 Smart Array Controller 462862 B21 HP P410 512 BBWC Smart Array Controller 462864 B21 HP Smart Array P410 1G with FBWC 572532 B21 HP Smart Array P410 512MB with FBWC 578230 B21 Smart Array P411 Controller Smart Array P411 Controller Smart Array P411 Controller Smart Array ...

Страница 22: ...hp com products quickspecs 12566_na 12566_na html SC11Xe HBA http h18004 www1 hp com products quickspecs 12617_na 12617_na html SC44Ge HBA http h18000 www1 hp com products quickspecs 12460_na 12460_na html Smart Array E200 Controller NOTE NOTE NOTE NOTE Please see the following Controller QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs...

Страница 23: ... Internal Tape Drive NOTE NOTE NOTE NOTE Mounts inside the 1U SAS Rack Mount Kit AE459A DW085A HP StorageWorks LTO 3 Ultrium 920 SAS Internal Tape Drive NOTE NOTE NOTE NOTE Mounts inside the 1U SAS Rack Mount Kit AE459A EH847A DAT 320 WW SAS External Tape Drive AJ828A SCSI Rack Mount Tape Solutions SCSI Rack Mount Tape Solutions SCSI Rack Mount Tape Solutions SCSI Rack Mount Tape Solutions NOTE NO...

Страница 24: ...1 LTO 4 Ultrium 1840 SCSI Drive Library AJ035A HP StorageWorks MSL4048 2 LTO 4 Ultrium 1760 SAS Drive Library AK380A HP StorageWorks MSL4048 1 Ultrium 960 SCSI Drive Library AG322A HP StorageWorks MSL4048 1 Ultrium 920 SAS Drive Library AH560A NOTE NOTE NOTE NOTE Please reference the QuickSpecs for Technical Specifications http www hp com go automation and additional information needed to create a...

Страница 25: ...B PCIe 4Gb FC Dual Port HBA AP768A Emulex Fibre Channel HBAs Emulex Fibre Channel HBAs Emulex Fibre Channel HBAs Emulex Fibre Channel HBAs HP StorageWorks 81E 8Gb SP PCI e FC HBA AJ762A HP 82E 8Gb Dual port PCI e FC HBA AJ763A HP StorageWorks FC2142SR 4Gb PCI e HBA A8002A QLogic Fibre Channel HBAs QLogic Fibre Channel HBAs QLogic Fibre Channel HBAs QLogic Fibre Channel HBAs HP StorageWorks 81Q PCI...

Страница 26: ... NOTE NOTE NOTE NOTE Rack mountable 25 drive 2 5 3G SAS 1 5G SATA 2U enclosure with 3Gb s SAS host connectivity and redundant power supplies NOTE NOTE NOTE NOTE Please see the QuickSpecs for Technical Specifications and additional information http h18000 www1 hp com products quickspecs 12652_na 12652_na html HP Uninterruptible Power HP Uninterruptible Power HP Uninterruptible Power HP Uninterrupti...

Страница 27: ...ch with Virtual Media AF602A 2x16 Server Console Switch with Virtual Media AF600A PS 2 Virtual Media Interface Adapter 1 pack NOTE NOTE NOTE NOTE Requires PS 2 and one USB port on server AF604A HP Server Console Switch KVM 0 x 2 x 8 port AF616A HP Server Console Switch KVM 0 x 2 x 16 port AF617A PS 2 Interface Adapter 1 pack 262588 B21 PS 2 Interface Adapter 8 pack 262587 B21 HP 1x4 Console Switch...

Страница 28: ... UH271E 24 Hour x 7 Day Coverage 3 Years Electronic UH272E NOTE NOTE NOTE NOTE Use one of the following Smart Buy Care Packs to attach 3 year 4 Hour On site Service to Smart Buy servers For other service levels order standard Care Pack part numbers DL18x Smart Buy 4 Hour On site Service 5 Day x 13 Hour Coverage 3 Years Electronic UK161E DL18x Smart Buy 4 Hour On site Service 7 Day x 24 Hour Covera...

Страница 29: ... GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 GB Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Standard 4 GB Standard 4 GB Standard 4 GB Standard 4 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty Empty ...

Страница 30: ...e MDL Drives SATA Hot Plug LFF 3 5 inch Midline MDL Drives SATA Hot Plug LFF 3 5 inch Midline MDL Drives SATA Hot Plug LFF 3 5 inch Midline MDL Drives Quantity Quantity Quantity Quantity Supported Supported Supported Supported Position Position Position Position Supported Supported Supported Supported Controller Controller Controller Controller 2TB 3G SATA 7 2K 1TB 3G SATA 7 2K 750GB 3G SATA 7 2K ...

Страница 31: ... 2K 160GB 1 5G SATA 7 2K Up to 8 1 8 HP Smart Array E200 128 BBWC Controller HP Smart Array P400 256 MB Controller HP Smart Array P410 Controller HP Smart Array P212 Controller HP Smart Array E500 256 MB Controller HP Smart Array P800 512 BBWC Controller HP SC44Ge Host Bus Adapter NOTE NOTE NOTE NOTE When using the SC44Ge with SATA Hard Drives 1 5G SATA Hard Drives are required HP SC11Xe Host Bus ...

Страница 32: ...ler Controller Controller Part Controller Part Controller Part Controller Part Number Number Number Number HP StorageWorks SCSI HP StorageWorks SCSI HP StorageWorks SCSI HP StorageWorks SCSI Tape Drives External Tape Drives External Tape Drives External Tape Drives External LTO 1 Ultrium 232 LTO 2 Ultrium 448 LTO 3 Ultrium 920 LTO 3 Ultrium 960 LTO 4 Ultrium 1760 LTO 4 Ultrium 1840 DAT 40 DAT 72 D...

Страница 33: ...Fibre HP StorageWorks Fibre Tape Automation Tape Automation Tape Automation Tape Automation External External External External MSL2024 MSL4048 External Please consult the EBS connectivity matrix at http www hp com go ebs for detailed connectivity information N A HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX Removable Disk Backup Removable Disk Backup Removable Di...

Страница 34: ...d Input Wattage Max Rated Input Wattage Max Rated Input Wattage Max Rated Input Wattage Rating Rating Rating Rating Watts 893 888 872 862 862 862 Max Rated VA Max Rated VA Max Rated VA Max Rated VA Volt Amp 911 906 890 880 880 880 Efficiency Efficiency Efficiency Efficiency 84 84 5 86 87 87 87 Power Factor Power Factor Power Factor Power Factor 0 98 0 98 0 98 0 98 0 98 0 98 Leakage Current Leakage...

Страница 35: ...r Supply Output per power supply Rated Steady State Power Rated Steady State Power Rated Steady State Power Rated Steady State Power 750 W at 100 VAC 750 W at 200 VAC Maximum Peak Power Maximum Peak Power Maximum Peak Power Maximum Peak Power 750 W at 100 VAC 750W at 200 VAC System Inlet Temperature System Inlet Temperature System Inlet Temperature System Inlet Temperature Operating Operating Oper...

Страница 36: ...Controller Controller Controller Controller Disk Drive and Enclosure Disk Drive and Enclosure Disk Drive and Enclosure Disk Drive and Enclosure Interface Interface Interface Interface 3 G SAS Serial Attached SCSI 1 5 G SATA Serial Advanced Technology Attachment SAS Connectors SAS Connectors SAS Connectors SAS Connectors 2 internal SFF8484 x4 wide port connectors Cache Memory Speed Cache Memory Spe...

Страница 37: ...ite Cache Upgrade RAID 5 Distributed Data Guarding RAID 1 0 Striping Mirroring RAID 0 Striping Embedded NC7782 Dual Embedded NC7782 Dual Embedded NC7782 Dual Embedded NC7782 Dual Port PCI X Port PCI X Port PCI X Port PCI X 10 100 1000T Gigabit 10 100 1000T Gigabit 10 100 1000T Gigabit 10 100 1000T Gigabit network adapter network adapter network adapter network adapter Network Interface Network Int...

Страница 38: ...tt Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re sell HP equipment Copyright 2010 Hewlett Packard Development Company L P The information contained herein is subject to change without notice Microsoft and Windows NT are US registered trademarks of Microsoft Corporation AM...

Отзывы: