Time Protocols
SNTP: Viewing, Selecting, and Configuring
ii. Enter the IP address of the SNTP server you want the switch to
use for time synchronization.
Note:
This step replaces any previously configured server IP
address. If you will be using backup SNTP servers (requires use
of the CLI), then see “SNTP Unicast Time Polling with Multiple
SNTP Servers” on page 9-21.
iii. Press
[v]
to move the cursor to the
Server Version
field. Enter the
value that matches the SNTP server version running on the device
you specified in the preceding step (step ii). If you are unsure
which version to use, ProCurve recommends leaving this value
at the default setting of
3
and testing SNTP operation to determine
whether any change is necessary.
Note:
Using the menu to enter the IP address for an SNTP server
when the switch already has one or more SNTP servers config
ured causes the switch to delete the primary SNTP server from
the server list and to select a new primary SNTP server from the
IP address(es) in the updated list. For more on this topic, see
“SNTP Unicast Time Polling with Multiple SNTP Servers” on page
9-21.
iv. Press
[>]
to move the cursor to the
Poll Interval
field, then go to
6. In the
Poll Interval
field, enter the time in seconds that you want for a Poll
Interval. (For Poll Interval operation, see table 9-1, “SNTP Parameters”,
on page 9-5.)
7. Press
[Enter]
to return to the Actions line, then
[S]
(for
Save
) to enter the
new time protocol configuration in both the startup-config and running
config files.
9-7
Содержание ProCurve Series 2810
Страница 1: ...Management and Configuration Guide 2810 www procurve com ProCurve Series 2810 Switches N 10 XX ...
Страница 2: ......
Страница 3: ...ProCurve Series 2810 Switches July 2006 Management and Configuration Guide ...
Страница 56: ...Using the Menu Interface Where To Go From Here This page is intentionally unused 3 16 ...
Страница 98: ...Using the Web Browser Interface Status Reporting Features This page is intentionally unused 5 26 ...
Страница 240: ...Port Trunking Port Status and Configuration This page is intentionally unused 11 26 ...
Страница 320: ...File Transfers Copying Diagnostic Data to a Remote Host PC or Unix Workstation This page is intentionally unused A 24 ...
Страница 350: ...Monitoring and Analyzing Switch Operation Locating a Device This page is intentionally unused B 30 ...
Страница 404: ...MAC Address Management Viewing the MAC Addresses of Connected Devices This page is intentionally blank D 8 ...
Страница 408: ...Daylight Savings Time on ProCurve Switches Configuring Daylight Savings Time This page is intentionally unused E 4 ...
Страница 419: ... This page is intentionally unused ...