SROS Command Line Interface Reference Guide
DSX-1 Interface Configuration Command Set
5991-2114
© Copyright 2007 Hewlett-Packard Development Company, L.P.
596
loopback remote line inband
Use the
loopback remote line inband
command to send a loopback code to the remote unit to initiate a
line loopback. Use the
no
form of this command to send a loopdown code to the remote unit to deactivate
the loopback.
Syntax Description
inband
Uses the inband channel to initiate a full 1.544 Mbps physical (metallic) loopback
of the signal received by the remote unit from the network.
Default Values
No defaults necessary for this command.
Functional Notes
A remote loopback can only be issued if a bind does not exist on the interface and if the signaling mode is
set to
none
. The following diagram depicts the difference between a line and payload loopback.
Usage Examples
The following example initiates a remote line loopback using the inband channel:
ProCurve(config)#
interface t1 1/2
ProCurve(config-t1 1/2)#
loopback remote line inband