61195868L1-13C, August 2005
www.procurve.com
Copyright 2005 Hewlett-Packard Development Company, LP
Quick Start Guide
5990-8864
ProCurve Secure Router dl 1xE1 Module
J8454A
S
PECIFICATIONS
Operating Modes
E1/FE1 Frame Relay, E1/FE1 PPP, E1/FE1 Multilink
Frame Relay, E1/FE1 Multilink PPP, E1/FE1 HDLC
E1/FE1 Interface
Supported Standards: ITU-T G.703, ITU-T G.797,
ITU-T G.704 (CRC-4), ITU-T G.823
Line Rate: 2.048 Mbps ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
Receiver Sensitivity: -30 dB
FE1 Line Rate: Channelized timeslot (in multiples of
56/64 kbps)
Connector: RJ-48C
Clock Source
Network, internal
Diagnostics
Test Pattern Generation and Detection: QRSS, 511,
all ones, all zeros
Network loopbacks
Alarm generation and detection
Network performance data (15 minutes and 24 hours)
Compliance
FCC Part 15 Class A, EN 55022 Class A, EN 55024,
EN 61000-3-2, EN 61000-3-3
ACIF S016, ETSI TBR 12/TBR 13
EN 60950, IEC 60950, AS/NZS 60950
Physical
Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing at
30°C (86°F)
Non-Operating Temperature: -20°C to 70°C (-4°F to
158°F)
Non-Operating Relative Humidity: Up to 95 percent,
noncondensing at 30°C (86°C)
Altitude: Up to 3.05 km (10,000 ft)
I
NSTALLATION
I
NSTRUCTIONS
1.
Remove power from the unit.
2.
Slide the option module into the option slot until the module is
firmly seated against the chassis.
3.
Secure the screws at both edges of the module.
4.
Connect the cables to the associated device(s).
5.
Complete the installation of the base unit.
6.
Restore power to the unit.
Note
For safety information for the routers and all
modules, please refer to the safety and ESD
precautions in the ProCurve Secure Router
Installation Guide included in your router shipment.
E1 N
ETWORK
(RJ-48C) C
ONNECTION
P
INOUT
Pin
Name
Description
1
R1
Receive data from the network
2
T1
Receive data from the network
3
—
Unused
4
R
Transmit data toward the network
5
T
Transmit data toward the network
6-8
—
Unused
Note
An optional backup module is required for backup
applications.
For a description of the backup connection pinouts,
refer to the Quick Start Guide included with your
backup module