background image

61195868L1-13C, August 2005

www.procurve.com

Copyright 2005 Hewlett-Packard Development Company, LP

Quick Start Guide

5990-8864

ProCurve Secure Router dl 1xE1 Module

J8454A

S

PECIFICATIONS

Operating Modes

E1/FE1 Frame Relay, E1/FE1 PPP, E1/FE1 Multilink 
Frame Relay, E1/FE1 Multilink PPP, E1/FE1 HDLC

E1/FE1 Interface

Supported Standards: ITU-T G.703, ITU-T G.797,
ITU-T G.704 (CRC-4), ITU-T G.823
Line Rate: 2.048 Mbps ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
Receiver Sensitivity: -30 dB
FE1 Line Rate: Channelized timeslot (in multiples of
56/64 kbps)
Connector: RJ-48C

Clock Source

Network, internal

Diagnostics

Test Pattern Generation and Detection: QRSS, 511,
all ones, all zeros
Network loopbacks 
Alarm generation and detection
Network performance data (15 minutes and 24 hours)

Compliance

FCC Part 15 Class A, EN 55022 Class A, EN 55024,
EN 61000-3-2, EN 61000-3-3
ACIF S016, ETSI TBR 12/TBR 13
EN 60950, IEC 60950, AS/NZS 60950

Physical

Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing at 
30°C (86°F)
Non-Operating Temperature: -20°C to 70°C (-4°F to 
158°F)
Non-Operating Relative Humidity: Up to 95 percent, 
noncondensing at 30°C (86°C)
Altitude: Up to 3.05 km (10,000 ft)

I

NSTALLATION

 I

NSTRUCTIONS

1.

Remove power from the unit.

2.

Slide the option module into the option slot until the module is 
firmly seated against the chassis.

3.

Secure the screws at both edges of the module.

4.

Connect the cables to the associated device(s).

5.

Complete the installation of the base unit.

6.

Restore power to the unit.

Note

For safety information for the routers and all 
modules, please refer to the safety and ESD 
precautions in the ProCurve Secure Router 
Installation Guide
 included in your router shipment.

E1 N

ETWORK

 (RJ-48C) C

ONNECTION

 P

INOUT

Pin

Name

Description

1

R1

Receive data from the network

2

T1

Receive data from the network

3

Unused

4

R

Transmit data toward the network

5

T

Transmit data toward the network

6-8

Unused

Note

An optional backup module is required for backup 
applications.

For a description of the backup connection pinouts, 
refer to the Quick Start Guide included with your 
backup module

Отзывы: